Evidence map›Paper›PMID 38790295›Full record

ArticleBioengineering (Basel, Switzerland)2024

Automatic Estimation of the Interference Subspace Dimension Threshold in the Subspace Projection Algorithms of Magnetoencephalography Based on Evoked State Data.

Ruochen Zhao, Ruonan Wang, Yang Gao, Xiaolin Ning

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ruochen ZhaoInstitute of Large-Scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing 100191, China.ORCID 0009-0005-6258-0228
Ruonan WangInstitute of Large-Scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing 100191, China.ORCID 0000-0002-0018-8213
Yang GaoSchool of Instrumentation Science and Optoelectronic Engineering, Beihang University, Hangzhou 310051, China.
Xiaolin NingInstitute of Large-Scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing 100191, China.ORCID 0000-0003-3563-3601

Funding

Beijing Municipal Natural Science Foundation 4212012the National Natural Science Foundation of China 42388101
6 · The paper itself

Abstract

A class of algorithms based on subspace projection is widely used in the denoising of magnetoencephalography (MEG) signals. Setting the dimension of the interference (external) subspace matrix of these algorithms is the key to balancing the denoising effect and the degree of signal distortion. However, most current methods for estimating the dimension threshold rely on experience, such as observing the signal waveforms and spectrum, which may render the results too subjective and lacking in quantitative accuracy. Therefore, this study proposes a method to automatically estimate a suitable threshold. Time-frequency transformations are performed on the evoked state data to obtain the neural signal of interest and the noise signal in a specific time-frequency band, which are then used to construct the objective function describing the degree of noise suppression and signal distortion. The optimal value of the threshold in the selected range is obtained using the weighted-sum method. Our method was tested on two classical subspace projection algorithms using simulation and two sensory stimulation experiments. The thresholds estimated by the proposed method enabled the algorithms to achieve the best waveform recovery and source location error. Therefore, the threshold selected in this method enables subspace projection algorithms to achieve the best balance between noise removal and neural signal preservation in subsequent MEG analyses.

Indexed as

interference suppressionmagnetoencephalographyoptically pumped magnetometersubspace dimensionsubspace projection

Identifiers

PMID38790295
PMCPMC11117808

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.