Evidence map›Paper›PMID 38790284›Full record

ArticleBioengineering (Basel, Switzerland)2024

Effect of Plate Configuration in the Primary Stability of Osteotomies and Biological Reconstructions of Femoral Defects: Finite-Element Study.

M A Neto, M F Paulino, A M Amaro

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Biomechanics Analysis in Tissue Engineering.Bioengineering (Basel, Switzerland) · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

M A NetoUniversity of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, 3030-788 Coimbra, Portugal.ORCID 0000-0003-3030-0146
M F PaulinoUniversity of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, 3030-788 Coimbra, Portugal.ORCID 0000-0002-9838-1299
A M AmaroUniversity of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, 3030-788 Coimbra, Portugal.ORCID 0000-0001-5237-0773

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

objectiveOsteosynthesis is an alternative treatment for stabilizing femur-bone traumas. The initial stability of the fixation systems is one of the biomechanical parameters affecting implant failure and bone union, especially in surgeries of intercalary reconstructions after the removal of bone tumors. This study aimed to investigate the initial biomechanical effect of using one or two osteosynthesis plate configurations for femoral fixation and the effect of fastening the allograft to the osteosynthesis plate in the case of femoral allograft reconstructions.

methodsThree finite-element models of a femur with three different fixation conditions for a transverse osteotomy in the middle of the diaphysis, i.e., using one and two osteosynthesis plates and an intercalary allograft, were constructed. An eight-hole compression plate and a six-hole second plate were used to simulate osteosynthesis plates. The plate screws were tightened previously to the loading, and the tightening sequences simulate the bolt-tightening procedure in a surgical environment. The models were imported into the ADINA System for nonlinear analysis, using compression loads applied over the femur head.

resultsModels with the dual fixation systems had the most outstanding compression stiffness. The femur head movement in the dual plate system was 24.8% smaller than in the single plate system. A statistical analysis of a region of interest (VOI) placed in the femur diaphysis showed that the biomechanical effect of using the dual plate system is smaller in the osteotomy region than at the femur head, e.g., a displacement average decrease of only 5% between the two systems, while the maximum value decreases by 26.8%. The allograft fixation to the second osteosynthesis plate leads to an improvement in the system stability.

conclusionsThe results presented in this work show that including the bolt analysis in the femoral diaphysis osteotomy fixation will allow for capturing the nonlinear behavior of the osteotomy region more realistically. The stability of the intercalary reconstruction of the femoral diaphysis was higher when the allograft was fastened to the second osteosynthesis plate.

Indexed as

allograftbiological reconstructionfinite-element analysisosteosynthesis platesstability

Identifiers

PMID38790284
PMCPMC11117963

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.