Design and evaluation of an AR-based thermal imaging system for planning reconstructive surgeries.
Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
introductionThermal imaging can be used for the non-invasive detection of blood vessels of the skin. However, mapping the results to the patient currently lacks user-friendliness. Augmented reality may provide a useful tool to superimpose thermal information on the patient.
methodsA system to support planning in reconstructive surgery using a thermal camera was designed. The obtained information was superimposed on the physical object using a Microsoft HoloLens. An RGB, depth, and thermal camera were combined to capture a scene of different modalities and reconstruct a virtual scene in real time. To register the different cameras and the AR device, an active calibration target was developed and evaluated. A Vuforia marker was used to register the hologram in the virtual space. The accuracy of the projected hologram was evaluated in a laboratory setting with participants by measuring the error between the physical object and the hologram.
resultsThe AR-based system was evaluated by 21 participants in a laboratory setting. The mean projection error is 10.3 ± 9.4 mm. The system is able to stream a three-dimensional scene with augmented thermal information in real time at 5 frames per second. The active calibration target can be used independently of the environment.
conclusionThe calibration target provides an easy-to-use method for the registration of cameras capturing the visible to long-infrared spectral range. The inside-out tracking of the HoloLens in combination with a Vuforia marker is not accurate enough for the intended clinical use.