Evidence map›Paper›PMID 38786781›Full record

ArticleNanomaterials (Basel, Switzerland)2024

Chromatographic Assessment of Organic Compounds Using Carbon Nanotubes: The Relationship between Affinity and Dispersibility.

Taiyo Shimizu, Ryoichi Kishi, Atsushi Hirano, Ken Kokubo, Kenji Hata

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Taiyo ShimizuNano Carbon Device Research Center, National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, 1-1-1 Higashi, Tsukuba 305-8565, Ibaraki, Japan.ORCID 0000-0002-4366-4347
Ryoichi KishiNano Carbon Device Research Center, National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, 1-1-1 Higashi, Tsukuba 305-8565, Ibaraki, Japan.
Atsushi HiranoNanomaterials Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, 1-1-1 Higashi, Tsukuba 305-8565, Ibaraki, Japan.ORCID 0000-0002-4138-0308
Ken KokuboNano Carbon Device Research Center, National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, 1-1-1 Higashi, Tsukuba 305-8565, Ibaraki, Japan.ORCID 0000-0002-8776-7102
Kenji HataNano Carbon Device Research Center, National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, 1-1-1 Higashi, Tsukuba 305-8565, Ibaraki, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The affinity between carbon nanotubes (CNTs) and organic compounds is of substantial importance since it strongly relates to the dispersibility of CNTs in those compounds. Several affinity evaluation methods have been developed so far, and the concept of the Hansen solubility parameter is a representative method widely used in the field of nanocarbon materials. Here, we demonstrate that CNT-loaded silica columns can effectively assess the affinity of organic compounds for CNT surface by exploiting the chromatographic retention time as a criterion. Obtained trends of the affinity of organic compounds for CNT were compared to those based on Hansen solubility parameter distance values. Most organic compounds showed similar trends, but one exceptional compound was observed. Simple CNT dispersion tests were conducted with these organic compounds to demonstrate the advantage of the chromatographic assessment. Further, we conducted comparison experiments using a pyrene-functionalized column and other CNT-loaded columns to elucidate the characteristics of each CNT column. The chromatographic approaches using CNT columns would be beneficial for realizing CNT suspensions with improved CNT dispersibility.

Indexed as

carbon nanotubechromatographydispersibilityHansen solubility parameterretention time

Identifiers

PMID38786781
PMCPMC11124211

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.