Evidence map›Paper›PMID 38785689›Full record

ArticleBiosensors2024

Comparative Study of Field-Effect Transistors Based on Graphene Oxide and CVD Graphene in Highly Sensitive NT-proBNP Aptasensors.

Anastasiia Kudriavtseva, Stefan Jarić, Nikita Nekrasov, Alexey V Orlov, Ivana Gadjanski, Ivan Bobrinetskiy, Petr I Nikitin, Nikola Knežević

Abstract readComparative Study
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Anastasiia KudriavtsevaCenter for Probe Microscopy and Nanotechnology, National Research University of Electronic Technology, Zelenograd, Moscow 124498, Russia.ORCID 0000-0002-2239-4691
Stefan JarićBioSense Institute-Research and Development Institute for Information Technologies in Biosystems, University of Novi Sad, 21000 Novi Sad, Serbia.ORCID 0000-0001-7933-3542
Nikita NekrasovCenter for Probe Microscopy and Nanotechnology, National Research University of Electronic Technology, Zelenograd, Moscow 124498, Russia.ORCID 0000-0003-1417-0177
Alexey V OrlovProkhorov General Physics Institute of the Russian Academy of Sciences, Moscow 119991, Russia.ORCID 0000-0001-7408-3927
Ivana GadjanskiBioSense Institute-Research and Development Institute for Information Technologies in Biosystems, University of Novi Sad, 21000 Novi Sad, Serbia.ORCID 0000-0003-0713-7897
Ivan BobrinetskiyBioSense Institute-Research and Development Institute for Information Technologies in Biosystems, University of Novi Sad, 21000 Novi Sad, Serbia.ORCID 0000-0003-2380-2594
Petr I NikitinProkhorov General Physics Institute of the Russian Academy of Sciences, Moscow 119991, Russia.ORCID 0000-0003-1573-5512
Nikola KneževićBioSense Institute-Research and Development Institute for Information Technologies in Biosystems, University of Novi Sad, 21000 Novi Sad, Serbia.ORCID 0000-0002-1563-7763

Funding

European Commission 664387European Commission 872662European Commission 952259Russian Science Foundation 19-73-10205
6 · The paper itself

Abstract

Graphene-based materials are actively being investigated as sensing elements for the detection of different analytes. Both graphene grown by chemical vapor deposition (CVD) and graphene oxide (GO) produced by the modified Hummers' method are actively used in the development of biosensors. The production costs of CVD graphene- and GO-based sensors are similar; however, the question remains regarding the most efficient graphene-based material for the construction of point-of-care diagnostic devices. To this end, in this work, we compare CVD graphene aptasensors with the aptasensors based on reduced GO (rGO) for their capabilities in the detection of NT-proBNP, which serves as the gold standard biomarker for heart failure. Both types of aptasensors were developed using commercial gold interdigitated electrodes (IDEs) with either CVD graphene or GO formed on top as a channel of liquid-gated field-effect transistor (FET), yielding GFET and rGO-FET sensors, respectively. The functional properties of the two types of aptasensors were compared. Both demonstrate good dynamic range from 10 fg/mL to 100 pg/mL. The limit of detection for NT-proBNP in artificial saliva was 100 fg/mL and 1 pg/mL for rGO-FET- and GFET-based aptasensors, respectively. While CVD GFET demonstrates less variations in parameters, higher sensitivity was demonstrated by the rGO-FET due to its higher roughness and larger bandgap. The demonstrated low cost and scalability of technology for both types of graphene-based aptasensors may be applicable for the development of different graphene-based biosensors for rapid, stable, on-site, and highly sensitive detection of diverse biochemical markers.

Indexed as

Biosensing TechniquesGraphiteNatriuretic Peptide, BrainPeptide FragmentsTransistors, ElectronicAptamers, NucleotideBiomarkersElectrodesGoldHumansLimit of DetectionAptamers, NucleotideBiomarkersGoldgraphene oxideGraphiteNatriuretic Peptide, BrainPeptide Fragmentspro-brain natriuretic peptide (1-76)aptamerfield-effect transistorgraphenegraphene oxideheart failurepoint-of-care diagnostic

Identifiers

PMID38785689
PMCPMC11117807

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.