Evidence map›Paper›PMID 38784072›Full record

ArticleJournal of orthodontic science2024

Comparison of biomechanical performance of titanium and polyaryletheretherketone miniscrews at different insertion angles: A finite element analysis.

I Gusti Aju Wahju Ardani, Intan Vallentien Dwi Hariati, Alexander Patera Nugraha, Ida Bagus Narmada, Achmad Syaifudin, Ida Bagus Agastya Perkasa, Guruh Putra Gunung, Shailesh Deshmukh, Rozita Hassan

Abstract read
In one paragraph

Article in Journal of orthodontic science, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

I Gusti Aju Wahju ArdaniDepartment of Orthodontics, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, East Java, Indonesia.
Intan Vallentien Dwi HariatiDepartment of Orthodontics, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, East Java, Indonesia.
Alexander Patera NugrahaDepartment of Orthodontics, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, East Java, Indonesia.
Ida Bagus NarmadaDepartment of Orthodontics, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, East Java, Indonesia.
Achmad SyaifudinDepartment of Biomedical Engineering, Faculty of Intelligent Electrical and Informatics Technology, Institute of Technology Sepuluh Nopember, Surabaya, East Java, Indonesia.
Ida Bagus Agastya PerkasaDepartment of Orthodontics, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, East Java, Indonesia.
Guruh Putra GunungDepartment of Orthodontics, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, East Java, Indonesia.
Shailesh DeshmukhOrthodontic Department, Faculty of Dentistry, Bharati Vidyapeeth University Dental College and Hospital, India - Adjunct Professor Universitas Airlangga, Surabaya, East Java, Indonesia.
Rozita HassanOrthodontic Unit, Faculty of Dentistry, Universiti Sains Malaysia, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionOnly miniscrews [temporary anchoring devices, (TADs)] can provide absolute anchorage during orthodontic treatment. Titanium (Ti) is a fundamental material used in the production of miniscrews, but it has many disadvantages. Polyaryletheretherketone (PEEK) may have various benefits in the production of miniscrews. Finite element analysis (FEA) is a valid and reliable method for calculating stress, strain, and loading forces on complex structures and can be more time- and cost-efficient.

objectiveTo investigate the biomechanical performance of Ti and PEEK as miniscrew biomaterials employing FEA. MATERIALS AND

methodsThis study is a 3-D (3D) simulation with FEA. First, 3D miniscrew modeling is done using Ti base material and PEEK (1.4 mm × 6 mm size), as well as 3D inter-radicular space bone modeling. The simulation was performed by modeling the insertion angles (30°, 60°, and 90°) and applying a 200-gram loading force. The biomechanical performance of the miniscrew was then determined using FEA.

resultsAs the angle of insertion increases, the tension on the bone decreases, the stress on the TADs increases, and the bone deformation decreases. Compared to TADs made of Ti and PEEK, TADs made of PEEK alone cause more bone stress than TADs made of Ti. The distortion in the maxilla is observed to be larger than in the mandibular.

conclusionPEEK has greater stress on the bones than Ti and may be prospected as an alternative biomaterial for TAD fabrication, as documented in the FEA.

Indexed as

Dentistrymedicineorthodonticspolyaryletheretherketonetemporary anchorage devicetitanium

Identifiers

PMID38784072
PMCPMC11114449

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.