Evidence map›Paper›PMID 38781271›Full record

Observational studyPloS one2024

The reliability of a Biometrics device as a tool for assessing hand grip and pinch strength, in a Polish cohort-A prospective observational study.

Justyna Leszczak, Bogumiła Pniak, Mariusz Drużbicki, Agnieszka Guzik

Abstract readObservational Study
In one paragraph

Observational study in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Observational
  4. Evaluation of Hand-Grip Strength Measurement Using the Pablo Virtual Reality System in Young Adults.Medical science monitor : international medical journal of experimental and clinical research · 2025
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Justyna LeszczakInstitute of Health Sciences, Medical College, University of Rzeszów, Rzeszów, Poland.ORCID 0000-0001-8769-0048
Bogumiła PniakInstitute of Health Sciences, Medical College, University of Rzeszów, Rzeszów, Poland.
Mariusz DrużbickiInstitute of Health Sciences, Medical College, University of Rzeszów, Rzeszów, Poland.
Agnieszka GuzikInstitute of Health Sciences, Medical College, University of Rzeszów, Rzeszów, Poland.ORCID 0000-0002-4582-4383

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of the study was to assess the external and internal compatibility of the Biometrics E-LINK EP9 evaluation system device in the area of hand grip and pinch strength in the Polish population. The testing of hand grip and pinch strength was carried out among 122 healthy students. Two examiners performed hand grip and pinch strength measurements with a Biometrics E-LINK EP9 evaluation system device. Measurements were made for the right and left hands. The same people were tested again two weeks later, under the same conditions. The scores of one rater on the first and second tests were compared for reproducibility, and the scores of the two raters were compared to assess the reliability of the instrument. The measurements were found to be highly consistent both between the investigators and between the tests in the hand grip dynamometer test. The findings show high values of the Pearson's correlation coefficient equal or close to 1, as well as the interclass correlation coefficient (ICC) >0.9. Analysis of pinch strength measurements performed using the pinchmeter also found high values of the Pearson's correlation coefficient close to 1, as well as the interclass correlation coefficient >0.9; this reflects high agreement between the measurements performed by two investigators as well as assessments performed by one investigator at time intervals. These findings were confirmed by analyses performed using Bland-Altman plots. The measurements made with the Biometrics E-link EP9 evaluation system show high internal and external consistency in hand grip and pinch strength assessment. Biometrics E-link EP9 can be recommended for daily clinical practice.

Indexed as

Hand StrengthPinch StrengthAdultBiometryFemaleHumansMaleMuscle Strength DynamometerPolandProspective StudiesReproducibility of ResultsYoung Adult

Identifiers

PMID38781271
PMCPMC11115248

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked