SynthesisThe Cochrane database of systematic reviews2024
Dressings and securement devices to prevent complications for peripheral arterial catheters.
Synthesis in The Cochrane database of systematic reviews, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Effectiveness and Safety of Different Dressing and Securement Methods for Peripheral Intravenous Catheters: A Systematic Review and Meta-Analysis.International wound journal · 2026Pooled it
- Dressings and securement devices to prevent complications for peripheral arterial catheters.The Cochrane database of systematic reviews · 2024Pooled it
- Prevention of arterial catheter-related bloodstream infections: current evidence and future directions.Critical care (London, England) · 2026Review
- Intra-arterial catheters: An evidence-based review of device design, function and application.World journal of critical care medicine · 2025Review
- Impact of a 'Catheter Bundle' on Infection Rates and Economic Costs in the Intensive Care Unit: A Retrospective Cohort Study.Nursing reports (Pavia, Italy) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPeripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection.
objectivesTo evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH
methodsWe searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN
resultsWe included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS'
conclusionsThere is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.