Evidence map›Paper›PMID 38778565›Full record

ArticleJournal of applied clinical medical physics2024

Digital phantom versus patient-specific radiation dosimetry in adult routine thorax CT examinations.

Antonios E Papadakis, Vassiliki Giannakaki, John Stratakis, Marios Myronakis, Habib Zaidi, John Damilakis

Abstract readComparative Study
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Antonios E PapadakisUniversity Hospital of Heraklion, Medical Physics Department, Stavrakia, Heraklion, Crete, Greece.
Vassiliki GiannakakiUniversity Hospital of Heraklion, Medical Physics Department, Stavrakia, Heraklion, Crete, Greece.
John StratakisUniversity Hospital of Heraklion, Medical Physics Department, Stavrakia, Heraklion, Crete, Greece.
Marios MyronakisUniversity Hospital of Heraklion, Medical Physics Department, Stavrakia, Heraklion, Crete, Greece.
Habib ZaidiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland.ORCID https://orcid.org/0000-0001-7559-5297
John DamilakisUniversity of Crete, Medical School, Medical Physics Department, Stavrakia, Heraklion, Crete, Greece.

Funding

Euratom Reasearch and Training ProgramSINFONIA 945196
6 · The paper itself

Abstract

purposeThe aim of this study was to compare the organ doses assessed through a digital phantom-based and a patient specific-based dosimetric tool in adult routine thorax computed tomography (CT) examinations with reference to physical dose measurements performed in anthropomorphic phantoms.

methodsTwo Monte Carlo based dose calculation tools were used to assess organ doses in routine adult thorax CT examinations. These were a digital phantom-based dosimetry tool (NCICT, National Cancer Institute, USA) and a patient-specific individualized dosimetry tool (ImpactMC, CT Imaging GmbH, Germany). Digital phantoms and patients were classified in four groups according to their water equivalent diameter (D

resultsThe average percent difference of NCICT to TLD and ImpactMC to TLD dose measurements across all organs in both sexes was 13% and 6%, respectively. The average ± 1 standard deviation in dose values across all organs with NCICT, ImpactMC, and TLDs was ± 0.06 (mGy/mGy), ± 0.19 (mGy/mGy), and ± 0.13 (mGy/mGy), respectively. Organ doses decreased with increasing D

conclusionOrgan doses estimated with ImpactMC were in closer agreement to TLDs compared to NCICT. This may be attributed to the inherent property of ImpactMC methodology to generate phantoms that resemble the realistic anatomy of the examined patient as opposed to NCICT methodology that incorporates an anatomical discrepancy between phantoms and patients.

Indexed as

Monte Carlo MethodOrgans at RiskPhantoms, ImagingRadiation DosageRadiography, ThoracicTomography, X-Ray ComputedAdultFemaleHumansImage Processing, Computer-AssistedMaleRadiometryRadiotherapy Planning, Computer-AssistedThoraxCTdigital phantomsdosimetryexperimental phantomsMonte Carlo

Identifiers

PMID38778565
PMCPMC11244670

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.