Evidence map›Paper›PMID 38777946›Full record

ArticleInternational journal of computer assisted radiology and surgery2024

Simulated augmented reality-based calibration of optical see-through head mound display for surgical navigation.

Ho-Gun Ha, Kyeongmo Gu, Deokgi Jeung, Jaesung Hong, Hyunki Lee

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ho-Gun HaDivision of Intelligent Robot, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-myeon, Dalseong-gun, Daegu, 42988, Republic of Korea.
Kyeongmo GuDivision of Intelligent Robot, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-myeon, Dalseong-gun, Daegu, 42988, Republic of Korea.
Deokgi JeungDepartment of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-myeon, Dalseong-gun, Daegu, 42988, Republic of Korea.
Jaesung HongDepartment of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-myeon, Dalseong-gun, Daegu, 42988, Republic of Korea.
Hyunki LeeDivision of Intelligent Robot, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-myeon, Dalseong-gun, Daegu, 42988, Republic of Korea. hklee@dgist.ac.kr.

Funding

Ministry of Science and ICT, South Korea 24-IT-02Ministry of Trade, Industry and Energy P0025772National Research Foundation of Korea 2020R1I1A1A01064673
6 · The paper itself

Abstract

purposeCalibration of an optical see-through head-mounted display is critical for augmented reality-based surgical navigation. While conventional methods have advanced, calibration errors remain significant. Moreover, prior research has focused primarily on calibration accuracy and procedure, neglecting the impact on the overall surgical navigation system. Consequently, these enhancements do not necessarily translate to accurate augmented reality in the optical see-through head mount due to systemic errors, including those in calibration.

methodThis study introduces a simulated augmented reality-based calibration to address these issues. By replicating the augmented reality that appeared in the optical see-through head mount, the method achieves calibration that compensates for augmented reality errors, thereby reducing them. The process involves two distinct calibration approaches, followed by adjusting the transformation matrix to minimize displacement in the simulated augmented reality.

resultsThe efficacy of this method was assessed through two accuracy evaluations: registration accuracy and augmented reality accuracy. Experimental results showed an average translational error of 2.14 mm and rotational error of 1.06° across axes in both approaches. Additionally, augmented reality accuracy, measured by the overlay regions' ratio, increased to approximately 95%. These findings confirm the enhancement in both calibration and augmented reality accuracy with the proposed method.

conclusionThe study presents a calibration method using simulated augmented reality, which minimizes augmented reality errors. This approach, requiring minimal manual intervention, offers a more robust and precise calibration technique for augmented reality applications in surgical navigation.

Indexed as

Augmented RealitySurgery, Computer-AssistedCalibrationComputer SimulationEquipment DesignHeadHumansImaging, Three-DimensionalAugmented realityMedical imagingOptical see-through head mound displaySurgical navigation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials