Evidence map›Paper›PMID 38775601›Full record

ArticleDental press journal of orthodontics2024

Insertion torque, flexural strength and surface alterations of stainless steel and titanium alloy orthodontic mini-implants: an in vitro study.

Gustavo Lopes Puls, Guido Artemio Marañón-Vásquez, Christian Andrew Vargas Ramos, Caio Luiz Bitencourt Reis, Andréa Cândido Dos Reis, Maria Bernadete Sasso Stuani, Fábio Lourenço Romano, Mírian Aiko Nakane Matsumoto

Abstract readComparative Study
In one paragraph

Article in Dental press journal of orthodontics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Bioinformation · 2026
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Gustavo Lopes PulsUniversidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto, Departamento de Odontopediatria (Ribeirão Preto/SP, Brazil).ORCID http://orcid.org/0000-0002-4838-8935
Guido Artemio Marañón-VásquezUniversidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto, Especialização em Ortodontia (Ribeirão Preto/SP, Brazil).ORCID http://orcid.org/0000-0001-7029-0347
Christian Andrew Vargas RamosUniversidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto, Departamento de Odontopediatria (Ribeirão Preto/SP, Brazil).ORCID http://orcid.org/0000-0002-4418-0088
Caio Luiz Bitencourt ReisUniversidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto, Departamento de Odontopediatria (Ribeirão Preto/SP, Brazil).ORCID http://orcid.org/0000-0003-0606-1632
Andréa Cândido Dos ReisUniversidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto, Departamento de Materiais Odontológicos e Prótese (Ribeirão Preto/SP, Brazil).ORCID http://orcid.org/0000-0002-2307-1720
Maria Bernadete Sasso StuaniUniversidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto, Departamento de Odontopediatria (Ribeirão Preto/SP, Brazil).ORCID http://orcid.org/0000-0001-7791-9144
Fábio Lourenço RomanoUniversidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto, Departamento de Odontopediatria (Ribeirão Preto/SP, Brazil).ORCID http://orcid.org/0000-0003-1419-3520
Mírian Aiko Nakane MatsumotoUniversidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto, Departamento de Odontopediatria (Ribeirão Preto/SP, Brazil).ORCID http://orcid.org/0000-0001-8559-8715

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants.

methodsTwenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes.

resultsThe IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs.

conclusionsBased on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.

Indexed as

Dental AlloysDental ImplantsFlexural StrengthMaterials TestingMicroscopy, Electron, ScanningOrthodontic Anchorage ProceduresStainless SteelSurface PropertiesTitaniumTorqueBone DensityDental Stress AnalysisHumansIn Vitro TechniquesSpectrometry, X-Ray EmissionStress, MechanicalDental AlloysDental ImplantsStainless SteelTitanium

Identifiers

PMID38775601
PMCPMC11104944

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.