Evidence map›Paper›PMID 38774367›Full record

ArticleEuropean heart journal. Digital health2024

Evaluation of a novel cuffless photoplethysmography-based wristband for measuring blood pressure according to the regulatory standards.

Mariska van Vliet, Stefan H J Monnink, Mathijs J Kuiper, Jan C Constandse, Dieke Hoftijzer, Eelko Ronner

2 registry-linked trialsAbstract read
In one paragraph

Article in European heart journal. Digital health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05566886 completednot on this map

Multi Parameter Vital Signs Monitoring by the Corsano CardioWatch 287-2 Validation Study

TypeobservationalSponsorCorsano Health B.V.Ran2022 to 2023Enrolled100ConditionsCoronary Artery DiseaseArmsContinuous measurement of photoplethysmography at the wrist
NCT07322510 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Health Behaviour Change, Education on Risk Factor Reduction, Physical Activity Guidance, and Nutrition Counselling With a Remote Team to Support Patient Progress Using Technology in Synchronization With Medication Management and CardioWatch 287-2. (HEARTS in Sync + CardioWatch 287-2)

TypeinterventionalSponsorNova Scotia Health AuthorityRan2026 to 2029Enrolled216ConditionsWearable Device, Cardiovascular Disease, ASCVD Management, CHF - Congestive Heart FailureArmsRemote Patient Monitoring with Corsano CardioWatch 287-2
3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Observational
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Observational
  12. Review
  13. Review
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mariska van VlietDepartment of Cardiology, Reinier de Graaf Hospital, Reinier de Graafweg 5, 2625 AD Delft, The Netherlands.
Stefan H J MonninkDepartment of Cardiology, Reinier de Graaf Hospital, Reinier de Graafweg 5, 2625 AD Delft, The Netherlands.
Mathijs J KuiperDepartment of Cardiology, Reinier de Graaf Hospital, Reinier de Graafweg 5, 2625 AD Delft, The Netherlands.
Jan C ConstandseDepartment of Cardiology, Reinier de Graaf Hospital, Reinier de Graafweg 5, 2625 AD Delft, The Netherlands.
Dieke HoftijzerDepartment of Cardiology, Reinier de Graaf Hospital, Reinier de Graafweg 5, 2625 AD Delft, The Netherlands.
Eelko RonnerDepartment of Cardiology, Reinier de Graaf Hospital, Reinier de Graafweg 5, 2625 AD Delft, The Netherlands.ORCID https://orcid.org/0000-0002-4032-7863

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: Elevated blood pressure (BP) is a key risk factor in cardiovascular diseases. However, obtaining reliable and reproducible BP remains a challenge. This study, therefore, aimed to evaluate a novel cuffless wristband, based on photoplethysmography (PPG), for continuous BP monitoring. Methods and results: Predictions by a PPG-guided algorithm were compared to arterial BP measurements (in the sub-clavian artery), obtained during cardiac catheterization. Eligible patients were included and screened based on AAMI/European Society of Hypertension (ESH)/ISO Universal Standard requirements. The machine learning-based BP algorithm required three cuff-based initialization measurements in combination with ∼100 features (signal-derived and patient demographic-based). Ninety-seven patients and 420 samples were included. Mean age, weight, and height were 67.1 years (SD 11.1), 83.4 kg (SD 16.1), and 174 cm (SD 10), respectively. Systolic BP was ≤100 mmHg in 48 samples (11%) and ≥160 mmHg in 106 samples (25%). Diastolic BP was ≤70 mmHg in 222 samples (53%) and ≥85 mmHg in 99 samples (24%). The algorithm showed mean errors of ±3.7 mmHg (SD 4.4 mmHg) and ±2.5 mmHg (SD 3.7 mmHg) for systolic and diastolic BP, respectively. Similar results were observed across all genders and skin colours (Fitzpatrick I-VI). Conclusion: This study provides initial evidence for the accuracy of a PPG-based BP algorithm in combination with a cuffless wristband across a range of BP distributions. This research complies with the AAMI/ESH/ISO Universal Standard, however, further research is required to evaluate the algorithms performance in light of the remaining European Society of Hypertension recommendations. Clinical trial registration: www.clinicaltrials.gov, NCT05566886.

Indexed as

Blood pressureContinuous monitoringEvaluationInvasivePhotoplethysmographyWearable diagnostics

Identifiers

PMID38774367
PMCPMC11104472

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.