Evidence map›Paper›PMID 38774323›Full record

ArticleHeliyon2024

The exploration of a compound cone-beam CT contrast agent for diagnosis of human extracted cracked tooth.

Ziyang Hu, Yanni Hu, Shi Xu, Jia Zhuang, Dantong Cao, Antian Gao, Xin Xie, Zitong Lin

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ziyang HuDepartment of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Yanni HuDepartment of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Shi XuDepartment of Endodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Jia ZhuangDepartment of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Dantong CaoDepartment of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Antian GaoDepartment of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Xin XieDepartment of Stomatology, Third People's Hospital of Danyang City, Danyang, China.
Zitong LinDepartment of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: This study aims to investigate the use of sodium iodide (NaI), dimethyl sulfoxide (DMSO), ethyl alcohol, and ethyl acetate as cone-beam CT (CBCT) contrast agents for diagnosing cracked teeth. The optimal delay time for detecting the number of crack lines beyond the dentino-enamel junction (Nd), the number of cracks extending from the occlusal surface to the pulp cavity (Np), and the depth of the crack lines was explored. Methods: 14 human extracted cracked teeth were collected, 12 were used for enhanced scanning, and 2 were used for exploring the characteristic of crack lines. The teeth were scanned in 3 CBCT enhanced scanning (ES) modes: ES1 using meglumine diatrizoate (MD); ES2 using NaI and DMSO, ES3 using NaI, DMSO, ethyl alcohol and ethyl acetate. Three delay times (15mins, 30mins, and 60mins) were set for scanning. Nd, Np, and depth of crack lines were evaluated. Results: There were totally 24 crack lines on 12 cracked teeth. Nd was 10 in ES1 at 60mins, 24 in ES2 at 60mins and 24 in ES3 at 15mins. Np was 1 in ES1 at 60mins, 10 in ES2 at 60mins and 21 in ES3 at 60mins, and there were significantly different among them ( Conclusion: NaI, DMSO, ethyl alcohol and ethyl acetate show potential as contrast agents for enhanced CBCT scanning in diagnosis of cracked teeth and their depth

Indexed as

Cone-beam CTContrast agentCracked toothDelay timeSodium iodide

Identifiers

PMID38774323
PMCPMC11107363

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.