Evidence map›Paper›PMID 38769790›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2025

High in-vivo accuracy of a novel robotic-arm-assisted system for total knee arthroplasty.

Faseeh Zaidi, Craig M Goplen, Connor Fitz-Gerald, Scott M Bolam, Michael Hanlon, Jacob T Munro, Andrew P Monk

Abstract read
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. High in-vivo accuracy of a novel robotic-arm-assisted system for total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025
    Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Faseeh ZaidiDepartment of Surgery, University of Auckland, Auckland, New Zealand.ORCID http://orcid.org/0000-0002-5610-7582
Craig M GoplenDepartment of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand.
Connor Fitz-GeraldDepartment of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand.
Scott M BolamDepartment of Surgery, University of Auckland, Auckland, New Zealand.
Michael HanlonDepartment of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand.
Jacob T MunroDepartment of Surgery, University of Auckland, Auckland, New Zealand.
Andrew P MonkDepartment of Surgery, University of Auckland, Auckland, New Zealand.

Funding

Zimmer Biomet
6 · The paper itself

Abstract

purposeRobotic-assisted total knee arthroplasty (TKA) has been shown to improve the accuracy and precision of bony resections and implant position. However, the in vivo accuracy of the full surgical workflow has not been widely reported. The primary objective of this study is to determine the accuracy and precision of a robotic-arm-assisted system throughout the intraoperative workflow.

methodsThis was a retrospective cohort study of adult patients who underwent primary TKA with various workflows and alignment targets by three arthroplasty-trained surgeons with previous experience using the ROSA® Knee System (Zimmer Biomet) over a 3-month follow-up period. Accuracy and precision were determined by measuring the difference between various workflow time points, including the final preoperative plan (PP), robot-validated (RV) resection angle and postoperative radiographs (PR). The absolute mean difference between the measurements determined accuracy, and the standard deviation represented precision. The lateral distal femoral angle, medial proximal tibial angle, femoral flexion angle and tibial slope were measured on postoperative coronal long-leg radiographs and true short-leg lateral radiographs.

resultsA total of 77 patients were included in the final analyses. The accuracy for the coronal femoral angle was 1.62 ± 1.11°, 0.75 ± 0.79° and 1.96 ± 1.29° for the differences between PP and PR, PP and RV and RV and PR. The tibial coronal accuracy was 1.44 ± 1.03°, 0.81 ± 0.67° and 1.57 ± 1.14° for PP/PR, PP/RV and RV/PR, respectively. Femoral flexion accuracy was 1.39 ± 1.05°, 0.83 ± 0.59° and 1.81 ± 1.21° for PP/PR, PP/RV and RV/PR, respectively. Tibial slope accuracy was 0.99 ± 0.72°, 1.19 ± 0.87° and 1.63 ± 1.11°, respectively. The proportion of patients within 3° was 93.2%, 95.3%, 97.3% and 94.6% for the distal femur, proximal tibia, femoral flexion and tibial slope angles when the final intraoperative plan was compared to PRs. No patients had a postoperative complication at the final follow-up.

conclusionsThe ROSA Knee System has acceptable accuracy and precision of coronal and sagittal plane resections with few outliers at various steps throughout the platform's entire workflow in vivo. LEVEL OF EVIDENCE: Level III.

Indexed as

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresAgedAged, 80 and overFemaleHumansKnee JointMaleMiddle AgedRetrospective StudiesTibiaWorkflowaccuracyrobotic surgeryROSA total knee systemtotal knee arthroplasty

Identifiers

PMID38769790
PMCPMC11716351

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.