Evidence map›Paper›PMID 38769199›Full record

ReviewAbdominal radiology (New York)2024

Standardizing technical parameters and terms for abdominopelvic photon-counting CT: laying the groundwork for innovation and evidence sharing.

Shuai Leng, Giuseppe V Toia, Safa Hoodeshenas, Juan Carlos Ramirez-Giraldo, Yoad Yagil, Jonathan S Maltz, Kirsten Boedeker, Ke Li, Francis Baffour, Joel G Fletcher

Abstract readReview
PubMed Publisher
In one paragraph

Review in Abdominal radiology (New York), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Shuai LengDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.ORCID 0000-0002-6453-9481
Giuseppe V ToiaDepartments of Radiology and Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.ORCID 0000-0001-5794-2822
Safa HoodeshenasDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Juan Carlos Ramirez-GiraldoSiemens Medical Solutions USA Inc, Malvern, PA, USA.ORCID 0000-0001-8143-9514
Yoad YagilPD CT/AMI R&D Advanced Development, Philips Medical Systems, Haifa, Israel.ORCID 0000-0002-3277-4014
Jonathan S MaltzMolecular Imaging and Computed Tomography, GE Healthcare, Waukesha, WI, USA.ORCID 0000-0002-8281-255X
Kirsten BoedekerCanon Medical Systems Corporation, Otawara, Japan.
Ke LiDepartments of Radiology and Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.ORCID 0000-0002-2672-2672
Francis BaffourDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.ORCID 0000-0001-8005-4823
Joel G FletcherDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA. Fletcher.Joel@mayo.edu.ORCID 0000-0002-8941-5434

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photon-counting detector CT (PCD-CT) is a new technology that has multiple diagnostic benefits including increased spatial resolution, iodine signal, and radiation dose efficiency, as well as multi-energy imaging capability, but which also has unique challenges in abdominal imaging. The purpose of this work is to summarize key features, technical parameters, and terms, which are common amongst current abdominopelvic PCD-CT systems and to propose standardized terminology (where none exists). In addition, user-selectable protocol parameters are highlighted to facilitate both scientific evaluation and early clinical adoption. Unique features of PCD-CT systems include photon-counting detectors themselves, energy thresholds and bins, and tube potential considerations for preserved spectral separation. Key parameters for describing different PCD-CT systems are reviewed and explained. While PCD-CT can generate multi-energy images like dual-energy CT, there are new types of images such as threshold images, energy bin images, and special spectral images. The standardized terms and concepts herein build upon prior interdisciplinary consensus and have been endorsed by the newly created Society of Abdominal Radiology Photon-counting CT Emerging Technology Commission.

Indexed as

PhotonsRadiography, AbdominalTomography, X-Ray ComputedHumansPelvisRadiation DosageTerminology as TopicAbdomenComputed tomographyHumansPhotonsRadiation dosageStandardizationX-ray

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.