ArticleJACC. Asia2024
Tip Detection-Antegrade Dissection and Re-Entry With New Puncture Wire in CTO Intervention: Revolution Through 3D-Wiring.
Article in JACC. Asia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed.
- Angiography- and IVUS-tip-detection-guided 3D wiring for CTO and non-CTO percutaneous coronary interventions.Cardiovascular intervention and therapeutics · 2026Review
- Strategy Selection and Outcomes of Tip-Detection in CTO-PCI: Intraplaque Tracking vs Antegrade Dissection and Re-Entry.JACC. Advances · 2026Article
- Intravascular Plaque Modification With Rotational Atherectomy Technique for Recanalization of Heavily Calcified Chronic Total Occlusion.JACC. Case reports · 2026Article
- Reverse Tip Detection: An IVUS-Guided Strategy for Retrograde Wire Crossing in CTO PCI.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026Article
- Contemporary PCI in SCAD and the Role of Intravascular Imaging.JACC. Case reports · 2026Article
- Keys to Successful Tip Detection-Antegrade Dissection and Re-Entry (TD-ADR): Long-Axis Bias View Selection and 6 Approaches.JACC. Case reports · 2026Article
- Intentional Intimal Tracking Via a 6-F Guiding Catheter Using a Novel Puncture Wire: The Solo Technique.JACC. Case reports · 2026Article
- Tip detection-antegrade dissection and re-entry for bailout of iatrogenic dissection in an acute coronary syndrome patient: a case report.European heart journal. Case reports · 2026Article
- Tip detection-antegrade dissection and re-entry method as a bailout technique for coronary perforation in chronic total occlusion intervention: a case report.European heart journal. Case reports · 2026Article
- Temporal trends and outcomes of long coronary chronic total occlusion interventions: the Japanese CTO-PCI expert registry.Cardiovascular intervention and therapeutics · 2026Article
- Intravascular ultrasound-guided tip-detection antegrade dissection and re-entry as a bailout strategy for calcification-induced side-branch occlusion during complex percutaneous coronary intervention: a case report.European heart journal. Case reports · 2026Article
- Advances in Technology and Technique in Percutaneous Coronary Intervention: A Clinical Review.Internal medicine (Tokyo, Japan) · 2026Review
- Successful Combination of the Slipstream and the Tip Detection-Antegrade Dissection and Re-Entry Techniques for Chronic Total Occlusion.JACC. Case reports · 2025Article
- The Rise of Optical Coherent Tomography in Intracoronary Imaging: An Overview of Current Technology, Limitations, and Future Perspectives.Reviews in cardiovascular medicine · 2025Review
- HD-IVUS-Guided Tip Detection-Antegrade Dissection and Re-Entry (TD-ADR): First Experience in North America.JACC. Case reports · 2025Article
- First Attempt of Tip Detection-Antegrade Dissection and Re-Entry Using Conventional Intravascular Ultrasound in Coronary Intervention.JACC. Case reports · 2025Article
- Side branch preservation using tip detection-antegrade dissection re-entry after failed subintimal tracking and re-entry in chronic total occlusion: a case report.European heart journal. Case reports · 2024Article
- The Role of Coronary Imaging in Chronic Total Occlusions: Applications and Future Possibilities.Journal of cardiovascular development and disease · 2024Review
- Tip detection-antegrade dissection and re-entry (TD-ADR) with integrated fluoroscopic and intravascular ultrasound images in chronic total occlusion: first case report of integrated TD-ADR technique.European heart journal. Case reports · 2024Article
- Tip-detection antegrade dissection and re-entry into a seriously collapsed true lumen.European heart journal. Case reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
18 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The authors devised the tip detection (TD) method and developed AnteOwl WR intravascular ultrasound to standardize intravascular ultrasound-based 3-dimensional wiring for intraplaque tracking in chronic total occlusion (CTO)-percutaneous coronary intervention (PCI). The TD method also allowed antegrade dissection and re-entry (ADR). Combining TD-ADR with Conquest Pro 12 Sharpened Tip (CP12ST) wire, a new ADR wire with the strongest penetration force developed to date, enabled re-entry anywhere except calcification sites. Objectives: This study investigated the efficacy and feasibility of TD-ADR by comparison of procedural outcomes with Stingray-ADR in CTO-PCI. Methods: Twenty-seven consecutive CTO cases treated by TD-ADR with CP12ST wire between August 2021 and April 2023 and 27 consecutive CTO cases treated by Stingray-ADR with Conquest 8-20 (CP20) wire between March 2018 and July 2021 were retrospectively enrolled as the TD-ADR by CP12ST wire group and Stingray-ADR by CP20 wire group, respectively, from 4 facilities that could share technical information on these procedures. Results: The success rate of the ADR procedure was significantly improved (27 of 27 cases [100%] vs 18 of 27 cases [67%], respectively; Conclusions: TD-ADR by CP12ST wire can standardize highly accurate ADR in CTO-PCI.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.