Comparison of medical image interpretation time between conventional and automated methods of breast ultrasound.

Katyane Larissa Alves, Ruffo Freitas, Régis Resende Paulinelli, Marcus Nascimento Borges

Abstract readComparative Study
In one paragraph

Article in Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Katyane Larissa AlvesUniversidade Federal de Goiás GoiâniaGO Brazil Universidade Federal de Goiás, Goiânia, GO, Brazil.ORCID https://orcid.org/0000-0003-4205-0973
Ruffo FreitasUniversidade Federal de Goiás GoiâniaGO Brazil Universidade Federal de Goiás, Goiânia, GO, Brazil.ORCID https://orcid.org/0000-0003-4145-8598
Régis Resende PaulinelliUniversidade Federal de Goiás GoiâniaGO Brazil Universidade Federal de Goiás, Goiânia, GO, Brazil.ORCID https://orcid.org/0000-0001-9899-9278
Marcus Nascimento BorgesUniversidade Federal de Goiás GoiâniaGO Brazil Universidade Federal de Goiás, Goiânia, GO, Brazil.ORCID https://orcid.org/0000-0003-1253-0730

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To compare the medical image interpretation's time between the conventional and automated methods of breast ultrasound in patients with breast lesions. Secondarily, to evaluate the agreement between the two methods and interobservers. Methods: This is a cross-sectional study with prospective data collection. The agreement's degrees were established in relation to the breast lesions's ultrasound descriptors. To determine the accuracy of each method, a biopsy of suspicious lesions was performed, considering the histopathological result as the diagnostic gold standard. Results: We evaluated 27 women. Conventional ultrasound used an average medical time of 10.77 minutes (± 2.55) greater than the average of 7.38 minutes (± 2.06) for automated ultrasound (p<0.001). The degrees of agreement between the methods ranged from 0.75 to 0.95 for researcher 1 and from 0.71 to 0.98 for researcher 2. Among the researchers, the degrees of agreement were between 0.63 and 1 for automated ultrasound and between 0.68 and 1 for conventional ultrasound. The area of the ROC curve for the conventional method was 0.67 (p=0.003) for researcher 1 and 0.72 (p<0.001) for researcher 2. The area of the ROC curve for the automated method was 0. 69 (p=0.001) for researcher 1 and 0.78 (p<0.001) for researcher 2. Conclusion: We observed less time devoted by the physician to automated ultrasound compared to conventional ultrasound, maintaining accuracy. There was substantial or strong to perfect interobserver agreement and substantial or strong to almost perfect agreement between the methods.

Indexed as

Breast NeoplasmsUltrasonography, MammaryAdultCross-Sectional StudiesFemaleHumansImage Interpretation, Computer-AssistedMiddle AgedProspective StudiesTime FactorsBreast neoplasmsBreast ultrasoundDiagnostic imagingThree-dimensional imaging

Identifiers

PMID38765504
PMCPMC11075416

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.