ReviewAccounts of chemical research2024
Photoacoustic: A Versatile Nongenetic Method for High-Precision Neuromodulation.
Review in Accounts of chemical research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Micro/Nanorobots (MNRs) at the Intersection of Mechanobiology and Artificial Intelligence: An Emerging Frontier for Precision Nanomedicine.ACS nano medicine · 2026Review
- Crosstalk-free optical indicator-actuator combinations for bidirectional optogenetics.npj biomedical innovations · 2026Review
- Distinguishing Photoacoustic and Photothermal Neuron Stimulation Through Quantitative Mapping Spatiotemporal Field Evolution.bioRxiv : the preprint server for biology · 2026Article
- Miniaturized optically generated Bessel beam ultrasound for volumetric transcranial brain stimulation.Science advances · 2026Article
- Nanomaterial based photoacoustic interface for non-genetic neuromodulation.Nano futures · 2026Review
- Next-generation smart ophthalmic biomaterials: From passive response to active interaction and closed-loop control.Bioactive materials · 2026Review
- Very-large-scale mimetic optogenetic synapses for physical reservoir computing.Nature communications · 2026Article
- A flexible photoacoustic retinal prosthesis.Nature communications · 2025Article
- A flexible photoacoustic retinal prosthesis.bioRxiv : the preprint server for biology · 2025Article
- Instant noninvasive near-infrared deep brain stimulation using optoelectronic nanoparticles without genetic modification.Science advances · 2025Article
- Modulating neuroplasticity for chronic pain relief: noninvasive neuromodulation as a promising approach.Experimental & molecular medicine · 2025Review
- Tapered fiber probe-based optical cardiac pacemaker.Frontiers in bioengineering and biotechnology · 2025Article
- The Potential of Photoacoustic Imaging in Detecting and Managing Complex Wounds.Biomaterials research · 2025Review
- High-Precision Photoacoustic Neural Modulation Uses a Non-Thermal Mechanism.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
High-precision neuromodulation plays a pivotal role in elucidating fundamental principles of neuroscience and treating specific neurological disorders. Optical neuromodulation, enabled by spatial resolution defined by the diffraction limit at the submicrometer scale, is a general strategy to achieve such precision. Optogenetics offers single-neuron spatial resolution with cellular specificity, whereas the requirement of genetic transfection hinders its clinical application. Direct photothermal modulation, an alternative nongenetic optical approach, often associates a large temperature increase with the risk of thermal damage to surrounding tissues.Photoacoustic (also called optoacoustic) neural stimulation is an emerging technology for neural stimulation with the following key features demonstrated. First, the photoacoustic approach demonstrated high efficacy without the need for genetic modification. The generated pulsed ultrasound upon ns laser pulses with energy ranging from a few μJ to tens of μJ is sufficient to activate wild-type neurons. Second, the photoacoustic approach provides sub-100-μm spatial precision. It overcomes the fundamental wave diffraction limit of ultrasound by harnessing the localized ultrasound field generated through light absorption. A spatial precision of 400 μm has been achieved in rodent brains using a fiber-based photoacoustic emitter. Single-cell stimulation in neuronal cultures in vitro and in brain slices ex vivo is achieved using tapered fiber-based photoacoustic emitters. This precision is 10 to 100 times better than that for piezo-based low-frequency ultrasound and is essential to pinpoint a specific region or cell population in a living brain. Third, compared to direct photothermal stimulation via temperature increase, photoacoustic stimulation requires 40 times less laser energy dose to evoke neuron activities and is associated with a minimal temperature increase of less than 1 °C, preventing potential thermal damage to neurons. Fourth, photoacoustics is a versatile approach and can be designed in various platforms aiming at specific applications. Our team has shown the design of fiber-based photoacoustic emitters, photoacoustic nanotransducers, soft biocompatible photoacoustic films, and soft photoacoustic lenses. Since they interact with neurons through ultrasound without the need for direct contact, photoacoustic enables noninvasive transcranial and dura-penetrating brain stimulation without compromising high precision.In this Account, we will first review the basic principles of photoacoustic and discuss the key design elements of PA transducers for neural modulation guided by the principle. We will also highlight how these design goals were achieved from a materials chemistry perspective. The design of different PA interfaces, their unique capability, and their applications in neural systems will be reviewed. In the end, we will discuss the remaining challenges and future perspectives for this technology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.