Evidence map›Paper›PMID 38759211›Full record

ReviewAccounts of chemical research2024

Photoacoustic: A Versatile Nongenetic Method for High-Precision Neuromodulation.

Zhiyi Du, Guo Chen, Yueming Li, Nan Zheng, Ji-Xin Cheng, Chen Yang

Abstract readReview
In one paragraph

Review in Accounts of chemical research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. A flexible photoacoustic retinal prosthesis.bioRxiv : the preprint server for biology · 2025
    Article
  10. Article
  11. Review
  12. Tapered fiber probe-based optical cardiac pacemaker.Frontiers in bioengineering and biotechnology · 2025
    Article
  13. Review
  14. High-Precision Photoacoustic Neural Modulation Uses a Non-Thermal Mechanism.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zhiyi DuDepartment of Chemistry, Boston University, Boston, Massachusetts 02215, United States.
Guo ChenDepartment of Electrical and Computer Engineering, Boston University, Boston, Massachusetts 02215, United States.
Yueming LiDepartment of Electrical and Computer Engineering, Boston University, Boston, Massachusetts 02215, United States.
Nan ZhengDivision of Materials Science and Engineering, Boston University, Boston, Massachusetts 02215, United States.ORCID 0000-0002-7874-0055
Ji-Xin ChengDepartment of Electrical and Computer Engineering, Boston University, Boston, Massachusetts 02215, United States.ORCID 0000-0002-5607-6683
Chen YangDepartment of Chemistry, Boston University, Boston, Massachusetts 02215, United States.ORCID 0000-0001-9454-847X

Funding

Unveiling the mechanisms of ultrasound neuromodulation via spatially confined stimulation and temporally resolved recordingR01NS109794 · NINDS · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI CHENG, JI-XIN, HAN, XUE · 2018 to 2022
$3.6M
Massively Parallel Optoacoustic Retinal Stimulation at Micrometer-ResolutionR21EY035437 · NEI · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI YANG, CHEN · 2023 to 2025
$680k
Sub-millimeter precision wireless neuromodulation using a microwave split ring resonatorR21EY034275 · NEI · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI CHENG, JI-XIN · 2022 to 2024
$660k
NEI NIH HHS R21 EY034275NEI NIH HHS R21 EY035437NINDS NIH HHS R01 NS109794
6 · The paper itself

Abstract

High-precision neuromodulation plays a pivotal role in elucidating fundamental principles of neuroscience and treating specific neurological disorders. Optical neuromodulation, enabled by spatial resolution defined by the diffraction limit at the submicrometer scale, is a general strategy to achieve such precision. Optogenetics offers single-neuron spatial resolution with cellular specificity, whereas the requirement of genetic transfection hinders its clinical application. Direct photothermal modulation, an alternative nongenetic optical approach, often associates a large temperature increase with the risk of thermal damage to surrounding tissues.Photoacoustic (also called optoacoustic) neural stimulation is an emerging technology for neural stimulation with the following key features demonstrated. First, the photoacoustic approach demonstrated high efficacy without the need for genetic modification. The generated pulsed ultrasound upon ns laser pulses with energy ranging from a few μJ to tens of μJ is sufficient to activate wild-type neurons. Second, the photoacoustic approach provides sub-100-μm spatial precision. It overcomes the fundamental wave diffraction limit of ultrasound by harnessing the localized ultrasound field generated through light absorption. A spatial precision of 400 μm has been achieved in rodent brains using a fiber-based photoacoustic emitter. Single-cell stimulation in neuronal cultures in vitro and in brain slices ex vivo is achieved using tapered fiber-based photoacoustic emitters. This precision is 10 to 100 times better than that for piezo-based low-frequency ultrasound and is essential to pinpoint a specific region or cell population in a living brain. Third, compared to direct photothermal stimulation via temperature increase, photoacoustic stimulation requires 40 times less laser energy dose to evoke neuron activities and is associated with a minimal temperature increase of less than 1 °C, preventing potential thermal damage to neurons. Fourth, photoacoustics is a versatile approach and can be designed in various platforms aiming at specific applications. Our team has shown the design of fiber-based photoacoustic emitters, photoacoustic nanotransducers, soft biocompatible photoacoustic films, and soft photoacoustic lenses. Since they interact with neurons through ultrasound without the need for direct contact, photoacoustic enables noninvasive transcranial and dura-penetrating brain stimulation without compromising high precision.In this Account, we will first review the basic principles of photoacoustic and discuss the key design elements of PA transducers for neural modulation guided by the principle. We will also highlight how these design goals were achieved from a materials chemistry perspective. The design of different PA interfaces, their unique capability, and their applications in neural systems will be reviewed. In the end, we will discuss the remaining challenges and future perspectives for this technology.

Indexed as

NeuronsPhotoacoustic TechniquesAnimalsBrainHumansOptogenetics

Identifiers

PMID38759211
PMCPMC11154953

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.