Evidence map›Paper›PMID 38759067›Full record

ArticleTechnology and health care : official journal of the European Society for Engineering and Medicine2024

Development of sarcopenia assessment system using balance and gait ability: Preliminary tests in the elderly.

Shinbae Seo, Taekyu Kwon, Miyeon Shin, Hochoon Jeong, Mi Yu, Jongkyun Jeong, Changho Yu

Abstract read
In one paragraph

Article in Technology and health care : official journal of the European Society for Engineering and Medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Evaluating the Discriminative Performance of SARC-F and SARC-CalF in Identifying Functional Impairment in Community-Dwelling Older Adults.Physiotherapy research international : the journal for researchers and clinicians in physical therapy · 2026
    Observational
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shinbae SeoDepartment of Healthcare Engineering, Jeonbuk National University, Jeonju, Korea.
Taekyu KwonDivision of Biomedical Engineering, Jeonbuk National University, Jeonju, Korea.
Miyeon ShinDepartment of Energy Storage/Conversion Engineering of Graduate School (BK21 FOUR), Jeonbuk National University, Jeonju, Korea.
Hochoon JeongCybermedic, Co., Ltd., Gwangju, Korea.
Mi YuDivision of Biomedical Engineering, Jeonbuk National University, Jeonju, Korea.
Jongkyun JeongBukeong Hightech, Co., Gunsan, Korea.
Changho YuDepartment of Energy Storage/Conversion Engineering of Graduate School (BK21 FOUR), Jeonbuk National University, Jeonju, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSarcopenia is a disease that has recently become an issue, and research on various assessment methods is being conducted based on guidelines published for the diagnosis of sarcopenia. However, most assessments are complex because the inspector must measure each device to collect data, or the elderly must directly manipulate and get assessment.

objectiveIn this study, we developed an sarcopenia assessment system to assess and analyze various sarcopenia in one system.

methodsThe system consists of a scaffold sensor for balance ability assessment, a chair sensor for assessing the walking and lower extremity function, and a hand-held dynamometer for assessing grip strength. The balance pad consists of 326 FSR (Force Sensitive Resistor) sensors, and the accuracy is 10 kg/± 10%. The chair sensor applied four weight sensors (Loadcells) to the corner of the hip of the chair, and the accuracy is up to 150 kg ± 10%, and the resolution is 1 kg ± 10%. All data is transmitted to the software through a USB cable to assess sarcopenia through data analysis. The software has built a database to manage user-specific data. The assessment items consisted of "Short Physical Performance Battery (SPPB) Test" and "Hand Grip Strength Test." After completion, the software automatically terminates the assessment results and classifies sarcopenia according to the presented reference value.

resultsThe average value of the total SPPB test scores, including the balance test, gait speed test, and chair stand test, of all participants was 9.06 ± 1.97. The average values of the balance test, gait speed test, and chair stand test scores of all participants were 8.48 ± 2.80 sec (score 3.28 ± 1.23), 1.05 ± 0.26 m/sec (score 3.69 ± 0.79), and 16.05 ± 4.62 sec (score 2.08 ± 1.13). The average value of the hand grip test of all participants was 28.57 ± 2.94 kgf.

conclusionsA preliminary assessment was conducted on the elderly in their 60 s or older with the developed system, and its performance confirmed that the assessment and result analysis were conducted well without any errors in software or hardware. Future studies intend to verify the reliability and accuracy of the assessment results compared to the existing direct measurement methods. In addition, we would like to conduct a study to establish data on the muscle reduction index by age group of Koreans.

Indexed as

GaitGeriatric AssessmentHand StrengthPostural BalanceSarcopeniaAgedAged, 80 and overFemaleHumansMaleassessment systemhealthcarepreliminary testrehabilitationSarcopenia

Identifiers

PMID38759067
PMCPMC11191517

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.