SynthesisThe Cochrane database of systematic reviews2024
Hearing protection field attenuation estimation systems and associated training for reducing workers' exposure to noise.
Synthesis in The Cochrane database of systematic reviews, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Enhancing and sustaining noise attenuation from hearing protection devices: A mixed methods review of fit testing and instruction approaches.Journal of occupational and environmental hygiene · 2026Pooled it
- Hearing protection field attenuation estimation systems and associated training for reducing workers' exposure to noise.The Cochrane database of systematic reviews · 2024Pooled it
- Enhancing Hearing Protection: Evaluating Innovative Training Modalities for Optimal Fitting Outcomes.La Medicina del lavoro · 2025Trial
- Types of Evidence Synthesis Beyond Systematic Reviews in Evidence-Based Practice Publications in Audiology Research: A Tutorial.Journal of the American Academy of Audiology · 2026Article
- Effectiveness of the Healthy Hearing Promoting Program (HHPP) among workers in large-scale industries: A randomized controlled trial in central Thailand.Belitung nursing journal · 2026Article
- Steady-State Auditory Evoked Potentials in Workers Exposed to Occupational Noise.La Medicina del lavoro · 2025Article
- Global impact of Occupational Noise-Induced Hearing Loss (ONIHL): trends, gender disparities, and future projections: 1990-2036.Frontiers in global women's health · 2025Article
- Evaluation of Subtle Auditory Impairments with Multiple Audiological Assessments in Normal Hearing Workers Exposed to Occupational Noise.Brain sciences · 2023Article
- Personal attenuation ratings versus derated noise reduction ratings for hearing protection devices.The Journal of the Acoustical Society of America · 2022Article
- Correlation between Occupational Noise Exposure and Renal Dysfunction in Male Workers.Noise & healthArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundGlobal Burden of Disease studies identify hearing loss as the third leading cause of years lived with a disability. Their estimates point to large societal and individual costs from unaddressed hearing difficulties. Workplace noise is an important modifiable risk factor; if addressed, it could significantly reduce the global burden of disease. In practice, providing hearing protection devices (HPDs) is the most common intervention to reduce noise exposure at work. However, lack of fit of HPDs, especially earplugs, can greatly limit their effectiveness. This may be the case for 40% of users. Testing the fit and providing instructions to improve noise attenuation might be effective. In the past two decades, hearing protection fit-test systems have been developed and evaluated in the field. They are called field attenuation estimation systems. They measure the noise attenuation obtained by individual workers using HPDs. If there is a lack of fit, instruction for better fit is provided, and may lead to better noise attenuation obtained by HPDs.
objectivesTo assess: (1) the effects of field attenuation estimation systems and associated training on the noise attenuation obtained by HPDs compared to no instruction or to less instruction in workers exposed to noise; and (2) whether these interventions promote adherence to HPD use. SEARCH
methodsWe used CENTRAL, MEDLINE, five other databases, and two trial registers, together with reference checking, citation searching, and contact with study authors to identify studies. We imposed no language or date restrictions. The latest search date was February 2024. SELECTION CRITERIA: We included randomised controlled trials (RCTs), cluster-RCTs, controlled before-after studies (CBAs), and interrupted time-series studies (ITSs) exploring HPD fit testing in workers exposed to noise levels of more than 80 A-weighted decibels (or dBA) who use hearing protection devices. The unit 'dBA' reports on the use of a frequency-weighting filter to adjust sound measurement results to better reflect how human ears process sound. The outcome noise attenuation had to be measured either as a personal attenuation rating (PAR), PAR pass rate, or both. PAR pass rate is the percentage of workers who passed a pre-established level of sufficient attenuation from their HPDs, identified on the basis of their individual noise exposure. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed study eligibility, risk of bias, and extracted data. We categorised interventions as fit testing of HPDs with instructions at different levels (no instructions, simple instructions, and extensive instructions). MAIN
resultsWe included three RCTs (756 participants). We did not find any studies that examined whether fit testing and training contributed to hearing protector use, nor any studies that examined whether age, gender, or HPD experience influenced attenuation. We would have included any adverse effects if mentioned by the trial authors, but none reported them. None of the included studies blinded participants; two studies blinded those who delivered the intervention. Effects of fit testing of HPDs with instructions (simple or extensive) versus fit testing of HPDs without instructions Testing the fit of foam and premoulded earplugs accompanied by simple instructions probably does not improve their noise attenuation in the short term after the test (1-month follow-up: mean difference (MD) 1.62 decibels (dB), 95% confidence interval (CI) -0.93 to 4.17; 1 study, 209 participants; 4-month follow-up: MD 0.40 dB, 95% CI -2.28 to 3.08; 1 study, 197 participants; both moderate-certainty evidence). The intervention probably does not improve noise attenuation in the long term (MD 0.15 dB, 95% CI -3.44 to 3.74; 1 study, 103 participants; moderate-certainty evidence). Fit testing of premoulded earplugs with extensive instructions on the fit of the earplugs may improve their noise attenuation at the immediate retest when compared to fit testing without instructions (MD 8.34 dB, 95% CI 7.32 to 9.36; 1 study, 100 participants; low-certainty evidence). Effects of fit testing of HPDs with extensive instructions versus fit testing of HPDs with simple instructions Fit testing of foam earplugs with extensive instructions probably improves their attenuation (MD 8.62 dB, 95% CI 6.31 to 10.93; 1 study, 321 participants; moderate-certainty evidence) and also the pass rate of sufficient attenuation (risk ratio (RR) 1.75, 95% CI 1.44 to 2.11; 1 study, 321 participants; moderate-certainty evidence) when compared to fit testing with simple instructions immediately after the test. This is significant because every 3 dB decrease in noise exposure level halves the sound energy entering the ear. No RCTs reported on the long-term effectiveness of the HPD fit testing with extensive instructions. AUTHORS'
conclusionsHPD fit testing accompanied by simple instructions probably does not improve noise attenuation from foam and premoulded earplugs. Testing the fit of foam and premoulded earplugs with extensive instructions probably improves attenuation and PAR pass rate immediately after the test. The effects of fit testing associated with training to improve attenuation may vary with types of HPDs and training methods. Better-designed trials with larger sample sizes are required to increase the certainty of the evidence.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.