Evidence map›Paper›PMID 38757101›Full record

ArticleNorthern clinics of Istanbul2024

Comparison of two different respiratory monitoring systems with 4D-CT images for target volume definition in patients undergoing para-aortic nodal irradiation.

Sefika Arzu Ergen, Songul Karacam, Tuba Kurt Catal, Fazilet Oner Dincbas, Didem Colpan Oksuz, Ismet Sahinler

Abstract read
In one paragraph

Article in Northern clinics of Istanbul, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sefika Arzu ErgenDepartment of Radiation Oncology, Istanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, Istanbul, Turkiye.
Songul KaracamDepartment of Radiation Oncology, Istanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, Istanbul, Turkiye.
Tuba Kurt CatalDepartment of Radiation Oncology, Istanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, Istanbul, Turkiye.
Fazilet Oner DincbasDepartment of Radiation Oncology, Istanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, Istanbul, Turkiye.
Didem Colpan OksuzDepartment of Radiation Oncology, Istanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, Istanbul, Turkiye.
Ismet SahinlerDepartment of Radiation Oncology, Istanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, Istanbul, Turkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveToday, respiratory movement can be monitored and recorded with different methods during a simulation on a four-dimensional (4D) computed tomography (CT) device to be used in radiotherapy planning. A synchronized respiratory monitoring system (RPM) with an externally equipped device is one of these methods. Another method is to create 4D images of the patient's breathing phases without the need for extra equipment, with an anatomy-based software program integrated into the CT device. Our aim is to compare the RPM system and the software system (Deviceless) which are two different respiratory monitoring methods used in tracking moving targets during 4D-CT imaging and to assess their clinical usability.

methodsTen patients who underwent paraaortic nodal irradiation were enrolled. The simulation was performed using intravenous contrast material on a 4D-CT device with both respiratory monitoring methods. The right/left kidneys and renal arteries were chosen as references to evaluate abdominal organ movement. It was then manually contoured one by one on both sets of images. The images were compared volumetrically and geometrically after rigid reconstruction. The similarity between the contours was determined by the Dice index. Wilcoxon test was used for statistical comparisons.

resultsThe motion of the kidneys in all three directions was found to be 0.0 cm in both methods. The shifts in the right/left renal arteries were submillimetric. The Dice index showed a high similarity in both kidney and renal artery contours.

conclusionIn our study, no difference was found between RPM and Deviceless systems used for tracking and detection of moving targets during simulation in 4D-CT. Both methods can be used safely for radiotherapy planning according to the available possibilities in the clinic.

Indexed as

Four-dimensional computed tomographyrespiratory monitoring systemRPMsmart deviceless 4D

Identifiers

PMID38757101
PMCPMC11095336

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked