Protocol optimization for functional cardiac CT imaging using noise emulation in the raw data domain.

Zhye Yin, Pengwei Wu, Ashish Manohar, Elliot R McVeigh, Jed D Pack

Abstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Zhye YinGE HealthCare, Waukesha, Wisconsin, USA.
Pengwei WuGE HealthCare Technology & Innovation Center, Niskayuna, New York, USA.
Ashish ManoharDepartment of Medicine, Stanford University, Palo Alto, California, USA.
Elliot R McVeighDepartment of Bioengineering, Medicine, Radiology at University of California San Diego, San Diego, California, USA.
Jed D PackGE HealthCare Technology & Innovation Center, Niskayuna, New York, USA.

Funding

True 4DCT for Quantifying LV Dyssynchrony and Function for Targeting LV Lead Location in CRTR01HL144678 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI MCVEIGH, ELLIOT R · 2019 to 2022
$3.3M
Patient-specific thrombosis risk in atrial fibrillation by 4D CT imaging of atrial kinetics combined with computational fluid dynamicsR01HL160024 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DEL ALAMO, JUAN CARLOS, KAHN, ANDREW · 2021 to 2024
$2.7M
NHLBI NIH HHS R01 HL144678NHLBI NIH HHS R01 HL160024NIH HHS R01 HL14678
6 · The paper itself

Abstract

backgroundFour-dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across a number of heartbeats is still a concern. PURPOSE: A projection-domain noise emulation method is presented to generate accurate low-dose (mA modulated) 4D cardiac CT scans from high-dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable (ALARA).

methodsGiven a targeted low-dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high-dose data in projection domain. A spatially varying (i.e., channel-dependent) detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the ALARA dose threshold, a straightforward projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non-linear region of the detector response. Experiments were performed to validate the noise emulation method with both phantom and clinical data in terms of visual similarity, contrast-to-noise ratio (CNR), and noise-power spectrum (NPS).

resultsFor both phantom and clinical data, the low-dose emulated images exhibited similar noise magnitude (CNR difference within 2%), artifacts, and texture to that of the real low-dose images. The proposed channel-dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes.

conclusionsA detailed method to estimate system-dependent parameters for a raw-data based low dose emulation framework was described. The method produced realistic noise levels, artifacts, and texture with phantom and clinical studies. The proposed low-dose emulation method can be used to prospectively select patient-specific minimal-dose protocols for functional cardiac CT.

Indexed as

HeartPhantoms, ImagingRadiation DosageSignal-To-Noise RatioFour-Dimensional Computed TomographyHumansImage Processing, Computer-Assistedfunctional cardiac CTimage qualitylow‐dose emulationnoise injection

Identifiers

PMID38753583
PMCPMC11547861

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.