ArticleLasers in medical science2024
Development of a novel laboratory photodynamic therapy device: automated multi-mode LED system for optimum well-plate irradiation.
Article in Lasers in medical science, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Photodynamic therapy (PDT) is a targeted treatment method that utilizes a photosensitizer (PS) to induce cytotoxicity in malignant and non-malignant tumors. Optimization of PDT requires investigation of the selectivity of PS for the target tissues, irradiating light source, irradiation wavelengths, fluence rate, fluence, illumination mode, and overall treatment plan. In this study, we developed the Multi-mode Automatized Well-plate PDT LED Laboratory Irradiation System (MAWPLIS), an innovative device that automates time-consuming well plate light dosage/PS dose measurement experiment. The careful control of LED current and temperature stabilization in the LED module allowed the system to achieve high optical output stability. The MAWPLIS was designed by integrating a 3-axis moving system and motion controller, a quick-switching LED controller unit equipped with interchangeable LED modules capable of employing multiple wavelengths, and a TEC system. The proposed system achieved high optical output stability (1 mW) within the range of 0-500 mW, high wavelength stability (5 nm) at 635 nm, and high temperature stability (0.2 °C) across all radiation modes. The system's validation involved in vitro analysis using 5-ALA across varying concentrations, incubation periods, light exposures, and wavelengths in HT-29 colon cancer and WI-38 human lung fibroblast cell lines. Specifically, a combination of 405 nm and 635 nm wavelengths was selected to demonstrate enhanced strategies for colon cancer cell eradication and system validation. The MAWPLIS system represents a significant advancement in photodynamic therapy (PDT) research, offering automation and standardization of time-intensive experiments, high stability and precision, and improved PDT efficacy through dual-wavelength integration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.