Evidence map›Paper›PMID 38748752›Full record

ArticlePloS one2024

Evaluation of a new transpalpebral tonometer for self-measuring intraocular pressure.

Hidenaga Kobashi

Abstract readEvaluation Study
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Hidenaga KobashiToneasy Inc., Tokyo, Japan.ORCID 0000-0002-0767-4214

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe developed a novel transpalpebral self-tonometer called the TapEye tonometer (TET) based on palpation of the upper eyelid. Our goal was to evaluate a method for improving the accuracy of measuring intraocular pressure (IOP) through the eyelid.

methodsParticipants underwent standardized training by technicians and were required to be able to use the TET for study inclusion. Subsequently, a noncontact tonometer and Goldmann applanation tonometer (GAT) were used. All participants were instructed to measure their IOPs using the three tonometers at baseline (visit 1) and at 1 month (visit 2). At visit 2, the corrected IOP value measured by the TET (c-TET) was calculated using the difference between the TET and GAT measurements obtained at visit 1.

resultsNo significant correlations were found between the TET and GAT measurements at any visit, but the correlation between the c-TET and GAT measurements at visit 2 was significant. The mean difference between the c-TET and GAT measurements was 0.4 ± 3.7 mmHg in the right eye and 0.5 ± 3.4 mmHg in the left eye.

conclusionsAfter correcting the IOP based on the difference between the TET and GAT measurements at the initial visit, the corrected IOP value of the TET was correlated with that of the GAT at the second visit. The TET has the potential to address an unmet need by providing a tool for minimally invasive IOP measurements.

trial registrationClinical trial registration number: jRCTs032220268.

Indexed as

Intraocular PressureTonometry, OcularAdultAgedFemaleHumansMaleMiddle AgedYoung Adult

Identifiers

PMID38748752
PMCPMC11095731

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked