Evidence map›Paper›PMID 38748343›Full record

ArticleAnnals of biomedical engineering2026

Human and Porcine Lumbar Endplate Injury Risk in Repeated Flexion-Compression.

Concetta F Morino, Allison L Schmidt, Elizabeth Dimbath, Shea T Middleton, Jay K Shridharani, Jason R Kait, Maria A Ortiz-Paparoni, Josh Klinger, Joost Op 't Eynde, Cameron R Bass

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Concetta F MorinoDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA. concettamorino@gmail.com.ORCID http://orcid.org/0000-0001-7971-5663
Allison L SchmidtDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
Elizabeth DimbathDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
Shea T MiddletonDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
Jay K ShridharaniDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
Jason R KaitDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
Maria A Ortiz-PaparoniDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
Josh KlingerDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
Joost Op 't EyndeDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
Cameron R BassDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.

Funding

Medical Technology Enterprise Consortium W81XWH-15-9-0001
6 · The paper itself

Abstract

Low back pain (LBP) affects 50-80% of adults at some point in their lifetime, yet the etiology of injury is not well understood. Those exposed to repeated flexion-compression are at a higher risk for LBP, such as helicopter pilots and motor vehicle operators. Animal injury models offer insight into in vivo injury mechanisms, but interspecies scaling is needed to relate animal results to human. Human (n = 16) and porcine (n = 20) lumbar functional spinal units (FSUs) were loaded in repeated flexion-compression (1 Hz) to determine endplate fracture risk over long loading exposures. Flexion oscillated from 0 to 6° and peak applied compressive stress ranged from 0.65 to 2.38 MPa for human and 0.64 to 4.68 MPa for porcine specimens. Five human and twelve porcine injuries were observed. The confidence intervals for human and porcine 50% injury risk curves in terms of stress and cycles overlapped, indicating similar failure behavior for this loading configuration. However, porcine specimens were more tolerant to the applied loading compared to human, demonstrated by a longer time-to-failure for the same applied stress. Optimization revealed that time-to-failure in human specimens was approximately 25% that of porcine specimens at a given applied stress within 0.65-2.38 MPa. This study determined human and porcine lumbar endplate fracture risks in long-duration repeated flexion-compression that can be directly used for future equipment and vehicle design, injury prediction models, and safety standards. The interspecies scale factor produced in this study can be used for previous and future porcine lumbar injury studies to scale results to relevant human injury.

Indexed as

Low Back PainLumbar VertebraeSpinal FracturesAdultAnimalsCompressive StrengthFemaleHumansMaleMiddle AgedStress, MechanicalSwineFatigue loadingFlexion-compressionInjury riskLow back pain (LBP)Lumbar spine injuryWhole-body-vibration (WBV)

Identifiers

PMID38748343

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.