Evidence map›Paper›PMID 38742066›Full record

ArticleHeliyon2024

Patient-specific closed-loop model of the fontan circulation: Calibration and validation.

Jorge Aramburu, Bram Ruijsink, Radomir Chabiniok, Kuberan Pushparajah, Jordi Alastruey

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jorge AramburuUniversidad de Navarra, TECNUN Escuela de Ingeniería, P° Manuel Lardizabal 13, 20018, Donostia/San Sebastián, Spain.
Bram RuijsinkSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, SE1 7EH, London, UK.
Radomir ChabiniokSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, SE1 7EH, London, UK.
Kuberan PushparajahSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, SE1 7EH, London, UK.
Jordi AlastrueySchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, SE1 7EH, London, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Fontan circulation, designed for managing patients with a single functional ventricle, presents challenges in long-term outcomes. Computational methods offer potential solutions, yet their application in cardiology practice remains largely unexplored. Our aim was to assess the ability of a patient-specific, closed-loop, reduced-order blood flow model to simulate pulsatile blood flow in the Fontan circulation. Using one-dimensional models, we simulated the aorta, superior and inferior venae cavae, and right and left pulmonary arteries, while lumping heart chambers and remaining vessels into zero-dimensional models. The model was calibrated with patient-specific haemodynamic data from combined cardiac catheterisation and magnetic resonance exams, using a novel physics-based stepwise methodology involving simpler open-loop models. Testing on a 10-year-old, anesthetised patient, demonstrated the model's capability to replicate pulsatile pressure and flow in the larger vessels and ventricular pressure. Average relative errors in mean pressure and flow were 2.9 % and 3.6 %, with average relative point-to-point errors (RPPE) in pressure and flow at 5.2 % and 16.0 %. Comparing simulation results to measurements, mean aortic pressure and flow values were 50.7 vs. 50.4 mmHg and 41.6 vs. 41.9 ml/s, respectively, while ventricular pressure values were 28.7 vs. 27.4 mmHg. The model accurately described time-varying ventricular volume with a RPPE of 2.9 %, with mean, minimum, and maximum ventricular volume values for simulation results vs. measurements at 59.2 vs. 58.2 ml, 38.0 vs. 37.6 ml, and 76.0 vs. 74.4 ml, respectively. It provided physiologically realistic predictions of haemodynamic changes from pulmonary vasodilation and atrial fenestration opening. The new model and calibration methodology are freely available, offering a platform to virtually investigate the Fontan circulation's response to clinical interventions and explore potential mechanisms of Fontan failure. Future efforts will concentrate on broadening the model's applicability to a wider range of patient populations and clinical scenarios, as well as testing its effectiveness.

Indexed as

1-D modelCongenital heart diseaseFontan circulationParameter estimation

Identifiers

PMID38742066
PMCPMC11089314

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked