Evidence map›Paper›PMID 38741981›Full record

ArticleSurgical neurology international2024

A comparison of two versus five epineural sutures to achieve successful polyethylene glycol (PEG) nerve fusion in a rat sciatic nerve repair model.

Andrew Simon, Grace Victoria Gilbert, Alec Hayes Fisher, Parker Hunt Johnsen, Brandon Herb, Sebastián L Vega, Elliot Bodofsky, David A Fuller

Abstract read
In one paragraph

Article in Surgical neurology international, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Andrew SimonDepartment of Orthopaedic Surgery, Cooper Medical School of Rowan University, Camden, New Jersey, United States.
Grace Victoria GilbertDepartment of Orthopaedic Surgery, Cooper Medical School of Rowan University, Camden, New Jersey, United States.
Alec Hayes FisherDepartment of Plastic Surgery, Cooper Medical School of Rowan University, Camden, New Jersey, United States.
Parker Hunt JohnsenDepartment of Orthopaedic Surgery, Cooper Medical School of Rowan University, Camden, New Jersey, United States.
Brandon HerbDepartment of Biomedical Engineering, Rowan University, Glassboro, New Jersey, United States.
Sebastián L VegaDepartment of Orthopaedic Surgery, Cooper Medical School of Rowan University, Camden, New Jersey, United States.
Elliot BodofskyDepartment of Physical Medicine and Rehabilitation, Cooper Medical School of Rowan University, Camden, New Jersey, United States.
David A FullerDepartment of Orthopaedic Surgery, Cooper Medical School of Rowan University, Camden, New Jersey, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: We compared rates of successful polyethylene glycol (PEG) nerve fusion between two epineural suture repairs (2SR) and five epineural suture repairs (5SR) in a rat sciatic nerve transection neurorrhaphy model. We hypothesise that the two and five epineural neural suture repair groups will achieve a similar rate of PEG fusion. Methods: Twenty-five Lewis rats underwent bilateral sciatic nerve transection. Primary neurorrhaphy (PN) consisting of 2SR in one hind limb and 5SR in the contralateral hind limb was performed utilizing PEG fusion. Successful PEG fusion was confirmed by a distal muscle twitch after nerve stimulation proximal to the nerve fusion site. Sciatic nerve conduction velocity (SNCV) across the repair site and the force generated by tibialis anterior muscle (TAM) contraction were also compared between the 2SR and 5SR groups. Results: Success rates were 100% for the 2SR and the 5SR groups. No statistically significant differences in SNCV ( Conclusion: These findings demonstrate no significant difference in successful PEG fusion between the 2SR and 5SR groups. In addition, the findings demonstrate no statistically significant differences in SNCV or isometric tetanic TAM contractile force following sciatic nerve transection when performing a 2SR or 5SR PN in the setting of PEG fusion. Successful PEG fusion can be achieved acutely with either a two or five-epineural suture repair in a rat model.

Indexed as

ElectrophysiologyEpineural suturePolyethylene glycolRat models

Identifiers

PMID38741981
PMCPMC11090568

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.