Evidence map›Paper›PMID 38741691›Full record

ArticleJournal of ophthalmology2024

Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus.

Mika Ichimura, Satoshi Ueki, Takeo Fukuchi

Abstract read
In one paragraph

Article in Journal of ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mika IchimuraDivision of Ophthalmology and Visual Science, Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan.
Satoshi UekiDivision of Ophthalmology and Visual Science, Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan.ORCID https://orcid.org/0000-0002-7199-6111
Takeo FukuchiDivision of Ophthalmology and Visual Science, Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan.ORCID https://orcid.org/0000-0003-1795-6909

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The spot vision screener (SVS) has been widely used for eye health examinations of infants and young children. The purpose of this study was to evaluate the reproducibility of two SVS measurements in children with ophthalmological diseases. Methods: 29 patients aged 15 years or younger who visited our hospital for refraction examinations with SVS before and at least 60 minutes after administration of 2 drops of 1% cyclopentolate ophthalmic solution (before and after cycloplegia) were included in this study. Two SVS measurements were made before and after cycloplegia, respectively. Intraclass correlation coefficients (ICCs) and Bland-Altman analysis for spherical, spherical equivalent (SE), cylindrical, J0, and J45 values before and after cycloplegia were analyzed. Results: The mean age ± standard deviation (SD) of the 29 patients was 7.6 ± 2.4 years. There were 11 males and 18 females. The mean spherical values based on the SVS before and after cycloplegia were 0.42 ± 1.67 diopter (D), and 1.47 ± 2.23 D for the first measurement and 0.60 ± 1.74 D, and 1.42 ± 2.27 D for the second measurement, respectively. The mean cylindrical values based on SVS before and after cycloplegia were -1.45 ± 0.96 D and -1.65 ± 0.89 D for the first measurement and -1.58 ± 1.13 D and -1.66 ± 0.91 D for the second measurement, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values before cycloplegia were 0.95, 0.98, 0.83, 0.86, and 0.86, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values after cycloplegia were 0.99, 0.99, 0,87, 0.73, and 0.80, respectively. The Bland-Altman analysis of the first and second spherical and SE values before cycloplegia showed fan-shaped variation as hyperopia increased. Conclusions: Two consecutive SVS refraction measurements have a high degree of reproducibility for spherical and SE values but a low degree for cylindrical, J0, and J45 values. From these results, multiple measurements are required to obtain reliable results for cylindrical values.

Identifiers

PMID38741691
PMCPMC11090673

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.