Comparison of cardiac output estimates obtained from the Antares oscillometric pulse wave analysis algorithm and from Doppler transthoracic echocardiography.

Alexander Stäuber, Matthias Wilhelm Hoppe, Harald Lapp, Stefan Richter, Marc-Alexander Ohlow, Marcus Dörr, Cornelia Piper, Siegfried Eckert, Michael Thomas Coll-Barroso, Franziska Stäuber and 2 more

Abstract readComparative Study
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Alexander StäuberDepartment of Movement and Training Science, Leipzig University, Leipzig, Germany.ORCID 0000-0001-8744-236X
Matthias Wilhelm HoppeDepartment of Exercise Science, Philipps University of Marburg, Marburg, Germany.
Harald LappDepartment of Cardiology, Zentralklinik Bad Berka GmbH, Bad Berka, Germany.
Stefan RichterDepartment of Cardiology, SRH Klinikum Burgenlandkreis GmbH, Naumburg, Germany.
Marc-Alexander OhlowDepartment of Cardiology, SRH Wald-Klinikum GmbH, Gera, Germany.ORCID 0000-0001-9674-2129
Marcus DörrDepartment of Internal Medicine B, University Medicine Greifswald, Greifswald, Germany.ORCID 0000-0001-7471-475X
Cornelia PiperClinic for General and Interventional Cardiology/Angiology, Heart and Diabetes Center North Rhine-Westphalia, Bad Oeynhausen, Germany.
Siegfried EckertClinic for General and Interventional Cardiology/Angiology, Heart and Diabetes Center North Rhine-Westphalia, Bad Oeynhausen, Germany.
Michael Thomas Coll-BarrosoDepartment of Internal Medicine, Fliedner University of Applied Sciences, Düsseldorf, Germany.
Franziska StäuberDepartment of Sports Medicine, Chemnitz University of Technology, Chemnitz, Germany.
Nadine Abanador-KamperDepartment of Cardiology, HELIOS University Hospital Witten/Herdecke, Wuppertal, Germany.
Johannes BaulmannPraxis Dres. Gille/Baulmann, Rheinbach, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO.

methodsNon-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations.

resultsThe mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001).

conclusionsThe oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.

Indexed as

AlgorithmsCardiac OutputEchocardiography, DopplerPulse Wave AnalysisAgedAged, 80 and overFemaleHumansMaleMiddle AgedOscillometry

Identifiers

PMID38739601
PMCPMC11090340

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.