Evidence map›Paper›PMID 38738198›Full record

ArticleIndian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine2024

A Retrospective Database Analysis to Investigate if Electrolytes in Venous Blood are Equivalent to the Levels in Arterial Blood.

R N Devaki, Prajna Kasargod, An Roopa Urs, N Chandrika

Abstract read
In one paragraph

Article in Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Observational
  2. Article
  3. Comparison of Sodium, Potassium, Hemoglobin, and Glucose Levels by Blood Gas Analyzer and Hospital Laboratory Autoanalyzer in Emergency Department Settings: A Cross-sectional Study.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2025
    Article
  4. ABG Analyzer for Electrolyte Measurement in ICU Patients: To Do or Not to Do.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

R N DevakiDepartment of Biochemistry, Chamarajanagar Institute of Medical Sciences, Chamarajanagar, Karnataka, India.ORCID https://orcid.org/0009-0009-3180-3950
Prajna KasargodDepartment of Biochemistry, Chamarajanagar Institute of Medical Sciences, Chamarajanagar, Karnataka, India.ORCID https://orcid.org/0009-0007-3192-888X
An Roopa UrsDepartment of Pathology, Karwar Institute of Medical Sciences, Karwar, Karnataka, India.ORCID https://orcid.org/0000-0002-8150-0191
N ChandrikaDepartment of Biochemistry, Chamarajanagar Institute of Medical Sciences, Chamarajanagar, Karnataka, India.ORCID https://orcid.org/0000-0001-5500-6643

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In a critically ill patient, when an arterial blood sample is processed on an arterial blood gas (ABG) analyzer, it also measures electrolytes apart from analyzing the blood gases. The turnaround time for ABG analysis is way too less compared to the conventional electrolyte analysis with a serum sample. Objective: This study intends to investigate whether values of electrolytes estimated in arterial blood can substitute the routinely practiced method. Materials and methods: This is a retrospective cross-sectional study. The source of data is patients' reports of serum electrolytes and ABG analysis from the Clinical Biochemistry laboratory, CIMS Teaching Hospital, Chamarajanagar between January and June 2021. The electrolytes report of 200 patients from whom both arterial and venous blood samples were sent to the Clinical Biochemistry laboratory on the same day and at the same time for analysis were selected. The data was compiled, compared, and correlated using a suitable statistical tool. Results: The mean and standard deviation of sodium (135.62 ± 5.20 in venous vs 134.08 ± 8.49 in arterial blood), potassium (4.20 ± 0.64 vs 3.80 ± 0.75), and chloride (102.28 ± 4.99 vs 96.33 ± 8.11) were observed. However, when the concordance correlation coefficient and Bland-Altman plot analysis were made there was no agreement between electrolytes analyzed on serum in an autoanalyzer with that of ABG analyzer. Conclusion: We conclude that the electrolytes measured by a conventional autoanalyzer on a serum sample cannot be replaced by values analyzed on a blood gas analyzer. How to cite this article: Devaki RN, Kasargod P, Roopa Urs AN, Chandrika N. A Retrospective Database Analysis to Investigate if Electrolytes in Venous Blood are Equivalent to the Levels in Arterial Blood. Indian J Crit Care Med 2024;28(5):442-446.

Indexed as

ChlorideLaboratory researchPotassiumSodiumTurnaround time

Identifiers

PMID38738198
PMCPMC11080103

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.