Validation of the design of a high-sensitivity and high-resolution PET system for a preclinical PET/EPR hybrid scanner.

Heejong Kim, Yuexuan Hua, Chin-Tu Chen, Boris Epel, Subramanian Sundramoorthy, Howard Halpern, Chien-Min Kao

Abstract read
In one paragraph

Article in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Heejong KimDepartment of Radiology, University of Chicago, Chicago, IL 60637, USA.
Yuexuan HuaRaycan Technology Co, Ltd., Suzhou, Jiangsu, China.
Chin-Tu ChenDepartment of Radiology, University of Chicago, Chicago, IL 60637, USA.
Boris EpelDepartment of Radiation and Cellular Oncology, University of Chicago, Chicago, IL 60637, USA.
Subramanian SundramoorthyDepartment of Radiation and Cellular Oncology, University of Chicago, Chicago, IL 60637, USA.
Howard HalpernDepartment of Radiation and Cellular Oncology, University of Chicago, Chicago, IL 60637, USA.
Chien-Min KaoDepartment of Radiology, University of Chicago, Chicago, IL 60637, USA.

Funding

Very Low Frequency EPR Imaging in Vivo Phisiology P41 EB02034P41EB002034 · NIBIB · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2017
$16.1M
Radiation Biology of EPR Oxygen ImagesR01CA098575 · NCI · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2022
$4.5M
Improved Radiation Therapy of Hypoxic Tumor Regions by Integrated PET, EPR, and MR Imaging - Resubmission 01 - Revision - 1R01CA236385 · NCI · UNIVERSITY OF CHICAGO · PI CHEN, CHIN-TU, HALPERN, HOWARD J · 2020 to 2024
$3.3M
A preclinical integrated PET/EPR imaging system-Rev3R01EB029948 · NIBIB · UNIVERSITY OF CHICAGO · PI EPEL, BORIS, KAO, CHIEN-MIN · 2020 to 2023
$1.7M
Tileable DOI/TOF capable PET detector unit with flexible sampling/digital architecture for data acquisition?R03EB027343 · NIBIB · UNIVERSITY OF CHICAGO · PI KAO, CHIEN-MIN · 2018 to 2019
$162k
NCI NIH HHS R01 CA098575NCI NIH HHS R01 CA236385NIBIB NIH HHS P41 EB002034NIBIB NIH HHS R01 EB029948NIBIB NIH HHS R03 EB027343
6 · The paper itself

Abstract

We report the development of a high-sensitivity and high-resolution PET subsystem for a next-generation preclinical PET/EPR hybrid scanner for investigating and improving hypoxia imaging with PET. The PET subsystem consists of 14 detector modules (DM) installed within a cylindrical supporting frame whose outer and inner diameters are 115mm and 60mm, respectively. Each DM contains eight detector units (DU) in a row and each DU is made of a 12×12 array of 1×1×10mm

Indexed as

Electron Paramagnetic Resonance Oxygen ImagingHybrid ImagingPositron Emission TomographyTumor Hypoxia

Identifiers

PMID38736647
PMCPMC11086702

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.