Evidence map›Paper›PMID 38733024›Full record

ArticleSensors (Basel, Switzerland)2024

Intra and Inter-Device Reliabilities of the Instrumented Timed-Up and Go Test Using Smartphones in Young Adult Population.

Thâmela Thaís Santos Dos Santos, Amélia Pasqual Marques, Luis Carlos Pereira Monteiro, Enzo Gabriel da Rocha Santos, Gustavo Henrique Lima Pinto, Anderson Belgamo, Anselmo de Athayde Costa E Silva, André Dos Santos Cabral, Szymon Kuliś, Jan Gajewski and 5 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Thâmela Thaís Santos Dos SantosLaboratório de Estudos da Motricidade Humana, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil.
Amélia Pasqual MarquesDepartment of Physiotherapy, Speech Therapy and Occupational Therapy, Faculty of Medicine, University of São Paulo, São Paulo 05403-000, SP, Brazil.
Luis Carlos Pereira MonteiroInstituto de Ciências Biológicas, Universidade Federal do Pará, Belém 66075-110, PA, Brazil.ORCID 0000-0002-0416-5182
Enzo Gabriel da Rocha SantosInstituto de Ciências Exatas e Naturais, Universidade Federal do Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil.ORCID 0000-0002-8927-4491
Gustavo Henrique Lima PintoInstituto de Ciências Exatas e Naturais, Universidade Federal do Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil.
Anderson BelgamoInstituto Federal de São Paulo, Piracicaba 17607-220, SP, Brazil.ORCID 0000-0002-4302-7516
Anselmo de Athayde Costa E SilvaPrograma de Pós Graduação em Ciências do Movimento, Universidade Federal do Pará, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil.ORCID 0000-0001-5265-619X
André Dos Santos CabralCentro de Ciências Biológicas e da Saúde, Universidade do Estado do Pará, Tv. Perebebuí, 2623-Marco, Belém 66087-662, PA, Brazil.ORCID 0000-0002-3022-5847
Szymon KuliśFaculty of Rehabilitation, Józef Piłsudski University of Physical Education in Warsaw, Marymoncka 34, 00-968 Warsaw, Poland.ORCID 0000-0002-0810-7086
Jan GajewskiFaculty of Physical Education, Józef Piłsudski University of Physical Education in Warsaw, Marymoncka 34, 00-968 Warsaw, Poland.ORCID 0000-0002-2146-6198
Givago Silva SouzaInstituto de Ciências Biológicas, Universidade Federal do Pará, Belém 66075-110, PA, Brazil.ORCID 0000-0002-4525-3971
Tacyla Jesus da SilvaCentro de Ciências Biológicas e da Saúde-Campus VIII, Universidade Estadual do Pará, Av. Helía, s/n-Amapá, Marabá 68502-100, PA, Brazil.
Wesley Thyago Alves da CostaCentro de Ciências Biológicas e da Saúde-Campus VIII, Universidade Estadual do Pará, Av. Helía, s/n-Amapá, Marabá 68502-100, PA, Brazil.
Railson Cruz SalomãoCentro de Ciências Biológicas e da Saúde-Campus VIII, Universidade Estadual do Pará, Av. Helía, s/n-Amapá, Marabá 68502-100, PA, Brazil.
Bianca CallegariLaboratório de Estudos da Motricidade Humana, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil.ORCID 0000-0001-9151-3896

Funding

National Council for Scientific and Technological Development #102167/2022-2National Council for Scientific and Technological Development #309936/2022-5
6 · The paper itself

Abstract

The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants' bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland-Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment.

Indexed as

SmartphoneAccidental FallsAdultFemaleHumansMaleReproducibility of ResultsYoung Adultbiomechanical phenomenaprogram evaluationresearch instrument evaluationsmartphonetest reproducibilitytimed-up and go test

Identifiers

PMID38733024
PMCPMC11086236

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.