Evidence map›Paper›PMID 38730941›Full record

ArticleMaterials (Basel, Switzerland)2024

Design Optimization of Printed Multi-Layered Electroactive Actuators Used for Steerable Guidewire in Micro-Invasive Surgery.

Simon Toinet, Mohammed Benwadih, Helga Szambolics, Christine Revenant, David Alincant, Marine Bordet, Jean-Fabien Capsal, Nellie Della-Schiava, Minh-Quyen Le, Pierre-Jean Cottinet

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Simon ToinetUniversity Grenoble Alpes, CEA, LITEN DTNM, 38000 Grenoble, France.
Mohammed BenwadihUniversity Grenoble Alpes, CEA, LITEN DTNM, 38000 Grenoble, France.ORCID 0000-0002-9550-5356
Helga SzambolicsUniversity Grenoble Alpes, CEA, LITEN DTNM, 38000 Grenoble, France.ORCID 0000-0002-5337-2612
Christine RevenantUniversity Grenoble Alpes, CEA, LITEN DTNM, 38000 Grenoble, France.ORCID 0000-0003-0847-8351
David AlincantUniversity Grenoble Alpes, CEA, LITEN DTNM, 38000 Grenoble, France.
Marine BordetDepartment of Vascular and Endovascular Surgery, Hospices Civils de Lyon, 69500 Bron, France.ORCID 0000-0003-4224-6124
Jean-Fabien CapsalLGEF Laboratory, INSA Lyon, UR682, 69621 Villeurbanne, France.ORCID 0000-0003-2904-8422
Nellie Della-SchiavaDepartment of Vascular and Endovascular Surgery, Hospices Civils de Lyon, 69500 Bron, France.
Minh-Quyen LeLGEF Laboratory, INSA Lyon, UR682, 69621 Villeurbanne, France.ORCID 0000-0001-5907-159X
Pierre-Jean CottinetLGEF Laboratory, INSA Lyon, UR682, 69621 Villeurbanne, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To treat cardiovascular diseases (i.e., a major cause of mortality after cancers), endovascular-technique-based guidewire has been employed for intra-arterial navigation. To date, most commercially available guidewires (e.g., Terumo, Abbott, Cordis, etc.) are non-steerable, which is poorly suited to the human arterial system with numerous bifurcations and angulations. To reach a target artery, surgeons frequently opt for several tools (guidewires with different size integrated into angulated catheters) that might provoke arterial complications such as perforation or dissection. Steerable guidewires would, therefore, be of high interest to reduce surgical morbidity and mortality for patients as well as to simplify procedure for surgeons, thereby saving time and health costs. Regarding these reasons, our research involves the development of a smart steerable guidewire using electroactive polymer (EAP) capable of bending when subjected to an input voltage. The actuation performance of the developed device is assessed through the curvature behavior (i.e., the displacement and the angle of the bending) of a cantilever beam structure, consisting of single- or multi-stack EAP printed on a substrate. Compared to the single-stack architecture, the multi-stack gives rise to a significant increase in curvature, even when subjected to a moderate control voltage. As suggested by the design framework, the intrinsic physical properties (dielectric, electrical, and mechanical) of the EAP layer, together with the nature and thickness of all materials (EAP and substrate), do have strong effect on the bending response of the device. The analyses propose a comprehensive guideline to optimize the actuator performance based on an adequate selection of the relevant materials and geometric parameters. An analytical model together with a finite element model (FEM) are investigated to validate the experimental tests. Finally, the design guideline leads to an innovative structure (composed of a 10-stack active layer screen-printed on a thin substrate) capable of generating a large range of bending angle (up to 190°) under an acceptable input level of 550 V, which perfectly matches the standard of medical tools used for cardiovascular surgery.

Indexed as

design guidelineelectroactive polymerflexible actuatormedical applicationmulti-layer beamscreen-printingsteerable smart guidewire

Identifiers

PMID38730941
PMCPMC11085776

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.