ArticleMaterials (Basel, Switzerland)2024
Femtosecond Laser Fabrication of High-Linearity Liquid Metal-Based Flexible Strain Sensor.
Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Laser Micromachining for Bioelectronics: Past, Present, and Future.Small methods · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Liquid metal (LM) is widely used in flexible electronic devices due to its excellent metallic conductivity and ductility. However, the fabrication of LM flexible strain sensors with high sensitivity and linearity is still a huge challenge, since the resistance of LM does not change much with strain. Here, a highly sensitive and linear fully flexible strain sensor with a resistive sensing function is proposed. The sensor comprises an Fe-doped liquid metal (Fe-LM) electrode for enhanced performance. The design and manufacturing of flexible strain sensors are based on the technology of controlling surface wettability by femtosecond laser micro/nano-processing. A supermetalphobic microstructure is constructed on a polydimethylsiloxane (PDMS) substrate to achieve the selection adhesion of Fe-LM on the PDMS substrate. The Fe-LM-based flexible strain sensor has high sensitivity and linearity, a gauge factor (GF) up to 1.18 in the strain range of 0-100%, excellent linearity with an R
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.