Evidence map›Paper›PMID 38730359›Full record

Trial reportBMC pulmonary medicine2024

Comparison of a portable, pneumotach flow-sensor-based spirometer (Spirofy™) with the vitalograph alpha Touch™ spirometer in evaluating lung function in healthy individuals, asthmatics, and COPD patients-a randomized, crossover study.

Deepak Talwar, S Balamurugan, Mahavir Modi, Sundeep Salvi, Meena Lopez, Rushika Shah, Abhijit Vaidya, Monica Barne, Sapna Madas, Nandan Kulkarni and 2 more

Abstract readRandomized Controlled TrialComparative Study
In one paragraph

Trial report in BMC pulmonary medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Deepak TalwarDepartment of Pulmonology, Pulmonary Sleep & Critical Care, Metro Centre for Respiratory Diseases, WASOG Sarcoid Clinic, Noida, Uttar Pradesh, India.
S BalamuruganDepartment of Pulmonology, Chest & Diabetes Research Institute, Chennai, Tamil Nadu, India.
Mahavir ModiDepartment of Pulmonology, Ruby Hall Clinic, Pune, Mumbai, Maharashtra, India.
Sundeep SalviPulmocare Research & Education Foundation (PURE), Pune, Maharashtra, India.
Meena LopezDepartment of Medical Affairs, Cipla Ltd, Mumbai, Maharashtra, India. meena@cipla.com.
Rushika ShahDepartment of Medical Affairs, Cipla Ltd, Mumbai, Maharashtra, India.
Abhijit VaidyaDepartment of Medical Affairs, Cipla Ltd, Mumbai, Maharashtra, India.
Monica BarneTraining Research Programs, Chest Research & Training Pvt Ltd, Pune, Maharashtra, India.
Sapna MadasDepartment of Data Management & Statistics, Chest Research & Training Pvt Ltd, Pune, Maharashtra, India.
Nandan KulkarniCiplaMedTech, Cipla Ltd, Mumbai, Maharashtra, India.
Sandesh SawantDepartment of Medical Affairs, Cipla Ltd, Mumbai, Maharashtra, India.
Jaideep GogtayDepartment of Medical Affairs, Cipla Ltd, Mumbai, Maharashtra, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSpirofy™ is India's first portable, pneumotach flow-sensor-based digital spirometer developed to diagnose asthma and chronic obstructive pulmonary disease (COPD). In this study, we compared the performance of the Spirofy™ device with that of the Vitalograph Alpha Touch™ spirometer in measuring the lung capacities of healthy individuals, asthmatics, and COPD patients. We also assessed the inter-device variability between two Spirofy™ devices.

methodsIn a randomized, three-way crossover, open-label study, we measured the differences in forced expiratory volume in the first second (FEV

resultsNinety subjects participated in this study. The mean ± SD FVC values obtained from the Spirofy™ 1, Spirofy™ 2, and Vitalograph Alpha Touch™ devices were 2.60 ± 1.05 L, 2.64 ± 1.04 L, and 2.67 ± 1.04 L, respectively. The mean ± SD FEV

conclusionSpirofy™ is a portable and easy-to-use device and is as accurate as the standard Vitalograph Alpha Touch™ spirometer for the diagnosis of COPD and asthma.

trial registrationCTRI/2021/09/036492 (Clinical Trials Registry - India).

Indexed as

AsthmaCross-Over StudiesPulmonary Disease, Chronic ObstructiveSpirometryAdultAgedFemaleForced Expiratory VolumeHumansIndiaMaleMiddle AgedVital CapacityYoung AdultAsthmaChronic obstructive pulmonary diseaseForced expiratory volumeForced vital capacitySpirometer

Identifiers

PMID38730359
PMCPMC11088097

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked