Color Flow Ultrasound Spatial Sampling Beam Density for Partial Volume-Corrected Three-Dimensional Volume Flow (3DVF): Theory, Simulation, and Experiment.

Stephen Z Pinter, Jonathan M Rubin, Anne L Hall, J Brian Fowlkes, Oliver D Kripfgans

Abstract read
In one paragraph

Article in Ultrasound in medicine & biology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Stephen Z PinterDepartment of Radiology, University of Michigan, Ann Arbor, MI, USA. Electronic address: pinters@umich.edu.
Jonathan M RubinDepartment of Radiology, University of Michigan, Ann Arbor, MI, USA.
Anne L HallGE Healthcare, Wauwatosa, WI, USA.
J Brian FowlkesDepartment of Radiology, University of Michigan, Ann Arbor, MI, USA.
Oliver D KripfgansDepartment of Radiology, University of Michigan, Ann Arbor, MI, USA.

Funding

3D Umbilical Venous Blood Flow - A New Paradigm for Improving the Assessment of Fetal Growth Restriction.R01HD097756 · NICHD · BAYLOR COLLEGE OF MEDICINE · PI FOWLKES, JEFFREY B, LEE, WESLEY · 2019 to 2023
$3.2M
Assessment of Placental Blood Volume Flow and Function in IUGR Using a Transfer Function ModelR21HD095501 · NICHD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI RUBIN, JONATHAN M · 2019 to 2020
$448k
NICHD NIH HHS R01 HD097756NICHD NIH HHS R21 HD095501
6 · The paper itself

Abstract

objectiveThe purpose of this study was to quantify the accuracy of partial volume-corrected three-dimensional volume flow (3DVF) measurements as a function of spatial sampling beam density using carefully-designed parametric analyses in order to inform the target applications of 3DVF.

methodsExperimental investigations employed a mechanically-swept curvilinear ultrasound array to acquire 3D color flow (6.3 MHz) images in flow phantoms consisting of four lumen diameters (6.35, 4.88, 3.18 and 1.65 mm) with volume flow rates of 440, 260, 110 and 30 mL/min, respectively. Partial volume-corrected three-dimensional volume flow (3DVF) measurements, based on the Gaussian surface integration principle, were computed at five regions of interest positioned between depths of 2 and 6 cm in 1 cm increments. At each depth, the color flow beam point spread function (PSF) was also determined, using in-phase/quadrature data, such that 3DVF bias could then be related to spatial sampling beam density. Corresponding simulations were performed for a laminar parabolic flow profile that was sampled using the experimentally-measured PSFs. Volume flow was computed for all combinations of lumen diameters and the PSFs at each depth.

resultsAccurate 3DVF measurements, i.e., bias less than ±20%, were achieved for spatial sampling beam densities where at least 6 elevational color flow beams could be positioned across the lumen. In these cases, greater than 8 lateral color flow beams were present. PSF measurements showed an average lateral-to-elevational beam width asymmetry of 1:2. Volume flow measurement bias increased as the color flow beam spatial sampling density within the lumen decreased.

conclusionApplications of 3DVF, particularly those in the clinical domain, should focus on areas where a spatial sampling density of 6 × 6 (lateral x elevational) beams can be realized in order to minimize measurement bias. Matrix-based ultrasound arrays that possess symmetric PSFs may be advantageous to achieve adequate beam densities in smaller vessels.

Indexed as

Imaging, Three-DimensionalPhantoms, ImagingBlood Flow VelocityComputer SimulationUltrasonography, Doppler, ColorBeam densityColor flow ultrasoundColor power ultrasoundC-planeFlow phantomGaussian surface integration principlePartial volumePoint spread functionThree-dimensional imagingVolume flow