Evidence map›Paper›PMID 38728612›Full record

ArticleClinical orthopaedics and related research2024

Do Hounsfield Units From Intraoperative CT Scans Correlate With Preoperative Values?

Brendan M Striano, Alexander M Crawford, Harry M Lightsey, Chierika Ukogu, Jose I Acosta Julbe, Daniel C Gabriel, Andrew J Schoenfeld, Andrew K Simpson

Abstract read
In one paragraph

Article in Clinical orthopaedics and related research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Brendan M StrianoHarvard Combined Orthopaedic Residency Program, Harvard Medical School, Boston, MA, USA.
Alexander M CrawfordHarvard Combined Orthopaedic Residency Program, Harvard Medical School, Boston, MA, USA.
Harry M LightseyHarvard Combined Orthopaedic Residency Program, Harvard Medical School, Boston, MA, USA.
Chierika UkoguHarvard Combined Orthopaedic Residency Program, Harvard Medical School, Boston, MA, USA.
Jose I Acosta JulbeOrthopaedic and Arthritis Center for Outcomes Research, Brigham and Women's Hospital, Boston, MA, USA.ORCID 0000-0002-4727-7475
Daniel C GabrielHarvard Medical School, Boston, MA, USA.
Andrew J SchoenfeldDepartment of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
Andrew K SimpsonDepartment of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.ORCID 0000-0001-8731-3576

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThere is increasing interest in forecasting postoperative complications using bone density metrics. Vertebral Hounsfield unit measurements obtained from CT scans performed for surgical planning or other purposes, known as opportunistic CTs, have shown promise for their ease of measurement and the ability to target density measurement to a particular region of interest. Concomitant with the rising interest in prognostic bone density measurement use has been the increasing adoption of intraoperative advanced imaging techniques. Despite the interest in both outcome prognostication and intraoperative advanced imaging, there is little information regarding the use of CT-based intraoperative imaging as a means to measure bone density. QUESTIONS/PURPOSES: (1) Can vertebral Hounsfield units be reliably measured by physician reviewers from CT scans obtained intraoperatively? (2) Do Hounsfield units measured from intraoperative studies correlate with values measured from preoperative CT scans?

methodsTo be eligible for this retrospective study, patients had to have been treated with the use of an intraoperative CT scan for instrumented spinal fusion for either degenerative conditions or traumatic injuries between January 2015 and December 2022. Importantly, patients without a preoperative CT scan of the fused levels within 180 days before surgery or who were indicated for surgery because of infection, metastatic disease, or who were having revision surgery after prior instrumentation were excluded from the query. Of the 285 patients meeting these inclusion criteria, 53% (151) were initially excluded for the following reasons: 36% (102) had intraoperative CT scans obtained after placement of instrumentation, 16% (47) had undergone intraoperative CT scans but the studies were not accessible for Hounsfield unit measurement, and 0.7% (2) had prior kyphoplasty wherein the cement prevented Hounsfield unit measurement. Finally, an additional 19% (53) of patients were excluded because the preoperative CT and intraoperative CT were obtained at different peak voltages, which can influence Hounsfield unit measurement. This yielded a final population of 81 patients from whom 276 preoperative and 276 intraoperative vertebral Hounsfield unit measurements were taken. Hounsfield unit data were abstracted from the same vertebra(e) from both preoperative and intraoperative studies by two physician reviewers (one PGY3 and one PGY5 orthopaedic surgery resident, both pursuing spine surgery fellowships). For a small, representative subset of patients, measurements were taken by both reviewers. The feasibility and reliability of Hounsfield unit measurement were then assessed with interrater reliability of values measured from the same vertebra by the two different reviewers. To compare Hounsfield unit values from intraoperative CT scans with preoperative CT studies, an intraclass correlation using a two-way random effects, absolute agreement testing technique was employed. Because the data were formatted as multiple measurements from the same vertebra at different times, a repeated measures correlation was used to assess the relationship between preoperative and intraoperative Hounsfield unit values. Finally, a linear mixed model with patients handled as a random effect was used to control for different patient and clinical factors (age, BMI, use of bone density modifying agents, American Society of Anesthesiologists [ASA] classification, smoking status, and total Charlson comorbidity index [CCI] score).

resultsWe found that Hounsfield units can be reliably measured from intraoperative CT scans by human raters with good concordance. Hounsfield unit measurements of 31 vertebrae from a representative sample of 10 patients, measured by both reviewers, demonstrated a correlation value of 0.82 (95% CI 0.66 to 0.91), indicating good correlation. With regard to the relationship between preoperative and intraoperative measurements of the same vertebra, repeated measures correlation testing demonstrated no correlation between preoperative and intraoperative measurements (r = 0.01 [95% CI -0.13 to 0.15]; p = 0.84). When controlling for patient and clinical factors, we continued to observe no relationship between preoperative and intraoperative Hounsfield unit measurements.

conclusionAs intraoperative CT and measurement of vertebral Hounsfield units both become increasingly popular, it would be a natural extension for spine surgeons to try to extract Hounsfield unit data from intraoperative CTs. However, we found that although it is feasible to measure Hounsfield data from intraoperative CT scans, the obtained values do not have any predictable relationship with values obtained from preoperative studies, and thus, these values should not be used interchangeably. With this knowledge, future studies should explore the prognostic value of intraoperative Hounsfield unit measurements as a distinct entity from preoperative measurements. LEVEL OF EVIDENCE: Level III, diagnostic study.

Indexed as

Bone DensityPredictive Value of TestsSpinal FusionTomography, X-Ray ComputedAdultAgedAged, 80 and overFemaleHumansIntraoperative CareMaleMiddle AgedPostoperative ComplicationsReproducibility of ResultsRetrospective StudiesSpinal Diseases

Identifiers

PMID38728612
PMCPMC11419555

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.