Evidence map›Paper›PMID 38726583›Full record

ArticleOrthopaedic surgery2024

3D-printed Multifunctional Guide Plate for Fenestration and Screws Drill in Proximal Femoral Benign Tumor.

Yuxuan Zhang, Yi Guo, Zonghao Li, Bing Wang, Zhenfeng Li

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yuxuan ZhangDepartment of Orthopedics, Qilu Hospital of Shandong University, Jinan, China.
Yi GuoMontefiore Medical Center, Albert Einstein School of Medicine, New York, New York, USA.
Zonghao LiDepartment of Orthopedics, Qilu Hospital of Shandong University, Jinan, China.
Bing WangSchool of Mechanical Engineering, Shandong University, Jinan, China.
Zhenfeng LiDepartment of Orthopedics, Qilu Hospital of Shandong University, Jinan, China.ORCID https://orcid.org/0000-0002-7928-3853

Funding

Natural Science Foundation of Shandong Province ZR2021MH114
6 · The paper itself

Abstract

The accurate fenestration, screw implantation and assisting stabilizing-plate placement in surgery of benign tumors in the proximal femur needs be defined easily. The aim of this study was to investigate the value of 3D printed multifunctional guides plate (3D-MGP) based on computer aided design. Between January 2020 and June 2022, 17 patients (nine females and eight males) with benign proximal femoral tumor had lesion curettage and allograft combined with internal plate fixation using 3D-MGP. In this study, the patients had CT scans and a technician reconstructed the 3D images of tumor and the femur, a doctor designed the location and margin of the fenestration and screws, and integrated different functions into MGP for benign proximal femoral lesions, which assisted in precise localization, fenestration and screw drilling. Musculoskeletal Tumor Society (MSTS) scoring was used to evaluate lower extremity function. Bone healing and the screws location was assessed with the radiographs. All patients underwent successful surgery with complete resection of the tumor and internal fixation with using the 3D-MGP. The mean follow-up was 16.4 months. The operative time was 126.47 ± 18.44 min, intraoperative bleeding was 198.23 ± 67.94 mL, intraoperative fluoroscopy was 6.47 ± 0.62, postoperative drainage was 223.82 ± 119.51 mL, and MSTS score was 27.29 ± 1.31 points. There were no unplanned fenestration and improper screw fixation. The 3D-MGP enabled personalized and accurate location of tumor, fenestration, screw placement and assisted stabilizing-plate placement for the treatment of benign tumor of the proximal femur. This technique has the potential to shorten operative times, decrease intraoperative bleeding, and reduce radiation exposure to patients.

Indexed as

Bone PlatesBone ScrewsFemoral NeoplasmsPrinting, Three-DimensionalAdolescentAdultComputer-Aided DesignFemaleHumansMaleMiddle AgedYoung Adult3D‐printedFenestration guideMultifunctional guideProximal femurScrew drill guide

Identifiers

PMID38726583
PMCPMC11144502

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.