Evidence map›Paper›PMID 38725428›Full record

ArticleJournal of periodontal & implant science2024

Correlation between the size of released titanium particles and changes in the surface of dental implants during insertion into bone blocks: an

Waad Kheder, Ab Rani Samsudin, Soumya Sheela, Sausan Al Kawas

Abstract read
In one paragraph

Article in Journal of periodontal & implant science, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Waad KhederCollege of Dental Medicine, University of Sharjah, Sharjah, UAE. wkheder@sharjah.ac.ae.ORCID https://orcid.org/0000-0001-6938-9913
Ab Rani SamsudinCollege of Dental Medicine, University of Sharjah, Sharjah, UAE.ORCID https://orcid.org/0000-0003-0373-837X
Soumya SheelaResearch Institute for Medical and Health Sciences, University of Sharjah, Sharjah, UAE.ORCID https://orcid.org/0000-0002-1947-253X
Sausan Al KawasCollege of Dental Medicine, University of Sharjah, Sharjah, UAE.ORCID https://orcid.org/0000-0001-6118-4382

Funding

University of Sharjah 1701100127-P
6 · The paper itself

Abstract

purposeThis study investigated the size and amount of titanium particles immediately released following dental implant insertion into bovine bone blocks and aimed to correlate them with the surface roughness of the implants.

methodsTwelve bone blocks were prepared from bovine mandibles. Six tapered (group A) and 6 cylindrical (group B) dental implants were inserted into the bone blocks under water irrigation, following the standard drilling protocol. After insertion, the implants were immediately removed from the bone. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and atomic force microscopy were performed to investigate the released titanium particles and implant surface roughness, respectively. The amount of titanium ions in the irrigation water was measured using inductively coupled plasma mass spectrometry. Dynamic light scattering (DLS) was used to determine the size range of the released titanium particles.

resultsThe percentages of titanium content on the surface of implants decreased in both groups after implantation into bone blocks. SEM-EDX analysis confirmed the presence of titanium particles embedded in the implanted bone bed. Group B implants showed significantly higher concentrations of titanium ions in the collected water than group A implants (0.868 and 0.565 µg/L, respectively). Group A implants demonstrated high pre-implantation surface roughness, which led to a much greater decrease in post-implantation surface roughness than was observed for group B implants. DLS analysis showed that the titanium particles released from group A implants were within the nano-size range, whereas those released from group B implants were within the micro-size range.

conclusionsDental implant placement leads to a decrease in implant surface roughness and the immediate release of titanium particles into the peri-implant bone. Variations in the size range and amount of released particles were correlated with implant surface roughness. This finding has clinical implications and warrants additional

Indexed as

BoneDental implantIonsOsteotomyTitanium