Evidence map›Paper›PMID 38722379›Full record

ArticleSurgical endoscopy2024

Tailoring the wrap: intraoperative functional lumen imaging probe (FLIP) during hiatal hernia repair.

Hemasat Alkhatib, A J Haas, Ali M Kara, Clara Lai, Alejandro Feria, Sergio Bardaro, Amelia Dorsey, Kevin El-Hayek

Abstract read
In one paragraph

Article in Surgical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Guideline
  2. Article
  3. Article
  4. Future perspectives in esophageal manometry.World journal of gastrointestinal surgery · 2025
    Review
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hemasat AlkhatibDivision of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA. Alkhatib.hemasat@gmail.com.ORCID 0000-0002-5384-2741
A J HaasDivision of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA.
Ali M KaraDivision of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA.
Clara LaiDivision of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA.
Alejandro FeriaDivision of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA.
Sergio BardaroDivision of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA.
Amelia DorseyDivision of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA.
Kevin El-HayekDivision of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe introduction of the functional lumen imaging probe (FLIP) has provided objective, real-time feedback on the geometric variations with each component of a hiatal hernia repair (HHR). The utility of this technology in altering intraoperative decision-making has been scarcely reported. Herein, we report a single-center series of intraoperative FLIP during HHR.

methodsA retrospective review of electronic medical records between 2020 and 2022 was conducted and all patients undergoing non-recurrent HHR with FLIP were queried. Patient and hernia characteristics, intraoperative FLIP values and changes in decision-making, as well as early post-operative outcomes were reported. Both diameter and distensibility index (DI) were measured at 40 ml and 50 ml balloon inflation after hiatal dissection, after hiatal closure, and after fundoplication when indicated.

resultsThirty-three patients met inclusion criteria. Mean age was 62 ± 14 years and mean BMI was 28 ± 6 kg/m

conclusionFLIP measurements can be used intraoperatively to guide decision-making and alter management plan based on objective values. Long-term outcomes and further prospective studies are required to better delineate the value of this technology.

Indexed as

Hernia, HiatalHerniorrhaphyAgedFemaleFundoplicationHumansMaleMiddle AgedRetrospective StudiesDistensibility indexFLIP technologyFundoplicationHiatal hernia repairImpedance planimetryRefractory gastroesophageal reflux disease

Identifiers

PMID38722379
PMCPMC11133156

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.