Evidence map›Paper›PMID 38720360›Full record

ArticleJournal of nanobiotechnology2024

Greatly isolated heterogeneous circulating tumor cells using hybrid engineered cell membrane-camouflaged magnetic nanoparticles.

Xinbang Jiang, Xiangyun Zhang, Chen Guo, Zhuang Liu, Xiaofang Guo, Ziying Tian, Zimeng Wang, Jingxuan Yang, Xinglu Huang, Lailiang Ou

Abstract read
In one paragraph

Article in Journal of nanobiotechnology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Xinbang Jiang *Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China.
Xiangyun Zhang *Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China.
Chen GuoKey Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China.
Zhuang LiuKey Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China.
Xiaofang GuoKey Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China.
Ziying TianKey Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China.
Zimeng WangKey Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China.
Jingxuan YangKey Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China.
Xinglu HuangKey Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China. huangxinglu@nankai.edu.cn.
Lailiang OuKey Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China. ouyll@nankai.edu.cn.

Funding

National Key R&D Program of China 2022YFC2304202National Natural Science Foundation of China 82172093Tianjin Science and Technology Program 21JCYBJC01060
6 · The paper itself

Abstract

backgroundCirculating tumor cells (CTCs) are considered as a useful biomarker for early cancer diagnosis, which play a crucial role in metastatic process. Unfortunately, the tumor heterogeneity and extremely rare occurrence rate of CTCs among billions of interfering leukocytes seriously hamper the sensitivity and purity of CTCs isolation.

methodsTo address these, we firstly used microfluidic chips to detect the broad-spectrum of triple target combination biomarkers in CTCs of 10 types of cancer patients, including EpCAM, EGFR and Her2. Then, we constructed hybrid engineered cell membrane-camouflaged magnetic nanoparticles (HE-CM-MNs) for efficient capture of heterogeneous CTCs with high-purity, which was enabled by inheriting the recognition ability of HE-CM for various CTCs and reducing homologous cell interaction with leukocytes. Compared with single E-CM-MNs, HE-CM-MNs showed a significant improvement in the capture efficiency for a cell mixture, with an efficiency of 90%. And the capture efficiency of HE-CM-MNs toward 12 subpopulations of tumor cells was ranged from 70 to 85%. Furthermore, by using HE-CM-MNs, we successfully isolated heterogeneous CTCs with high purity from clinical blood samples. Finally, the captured CTCs by HE-CM-MNs could be used for gene mutation analysis.

conclusionsThis study demonstrated the promising potential of HE-CM-MNs for heterogeneous CTCs detection and downstream analysis.

Indexed as

Biomarkers, TumorCell MembraneCell SeparationMagnetite NanoparticlesNeoplastic Cells, CirculatingCell Line, TumorEpithelial Cell Adhesion MoleculeErb-b2 Receptor Tyrosine KinasesErbB ReceptorsHumansNeoplasmsBiomarkers, TumorEGFR protein, humanEpithelial Cell Adhesion MoleculeERBB2 protein, humanErb-b2 Receptor Tyrosine KinasesErbB ReceptorsMagnetite NanoparticlesCancer metastasisCirculating tumor cellsGenetic engineeringHeterogeneityHybrid cell membrane

Identifiers

PMID38720360
PMCPMC11077811

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.