ArticleAnalytica chimica acta2024
Large-volume RT-LAMP enables extraction-free amplification of HIV RNA from fingerstick plasma.
Article in Analytica chimica acta, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Extraction-Free Scalable Sample Preparation for the Rapid Detection of HIV in Blood Plasma.Analytical chemistry · 2026Article
- Advances in Virus Biorecognition and Detection Techniques for the Surveillance and Prevention of Infectious Diseases.Biosensors · 2025Review
- Development of a Highly Multiplexed RT-LAMP Assay for Coverage of Genetic Sequence Diversity.Analytical chemistry · 2025Article
- Point-of-care isothermal nucleic acid amplification tests: progress and bottlenecks for extraction-free sample collection and preparation.Expert review of molecular diagnostics · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundPoint-of-care (POC) nucleic acid amplification tests (NAAT) can significantly expand testing coverage, which is critical for infectious disease diagnostics and monitoring. The development of various isothermal amplification techniques greatly simplifies NAATs, but the cumbersome nucleic acid extraction step remains a bottleneck for the POC. Alternatively, extraction-free amplification, where crude samples are directly added into the assay, substantially simplifies the workflow. However, sample dilution is often needed in extraction-free amplification to reduce assay inhibition from sample matrices. Since NAATs are typically run at small volumes around 20 μL, the input sample quantity is therefore limited, resulting in an inevitable sensitivity loss.
resultsHere we explore the potential to perform isothermal amplification in larger reaction volumes to accommodate larger sample quantities, thereby improving sensitivity in extraction-free amplification. We demonstrated the approach by developing large-volume reverse transcription loop-mediated isothermal amplification (RT-LAMP) for HIV RNA detection from fingerstick plasma. We found that LAMP at reaction volumes up to 1 mL maintained the same performance. We then identified plasma dilution conditions needed to maintain the limit of detection in RT-LAMP. Subsequently, using inactivated HIV virus, we showed the successful detection of 24 HIV RNA copies in a 500 μL RT-LAMP reaction in the presence of 20 μL plasma (fingerstick volumes), translating to a viral load of 1200 copies per mL. To reduce the increased reagent cost with expanded reaction volumes, we further identified lower-cost reagents with maintained assay performance. Moreover, we showed that large-volume LAMP, compared to 20 μL reactions, could tolerate higher concentrations of various inhibitors in the sample, such as albumin and GuSCN. SIGNIFICANCE AND NOVELTY: NAATs are conventionally conducted at small reaction volumes. Here we demonstrated that LAMP can be run at large reaction volumes (over 100 μL) with maintained assay performance, allowing sample inhibition to be mitigated while accommodating larger sample quantities. The same strategy of expanding reaction volumes could be applied to other isothermal amplification methods and various POC applications, to streamline test workflows and/or improve assay sensitivity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.