Performance of the non-invasive point-of-care device, EzeCheck, for haemoglobin assessment in adults and children in community and institutional care settings.

Partha Pratim Das Mahapatra, Chaitali Roy, Komal Agarwal, Joy Banerjee, Sandeep Sharma

Abstract read
In one paragraph

Article in PLOS digital health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Partha Pratim Das MahapatraEzeRx Health Tech Pvt. Ltd, Bhubaneswar, Odisha, India.ORCID https://orcid.org/0000-0001-9682-233X
Chaitali RoyEzeRx Health Tech Pvt. Ltd, Bhubaneswar, Odisha, India.ORCID https://orcid.org/0000-0002-4437-8721
Komal AgarwalEzeRx Health Tech Pvt. Ltd, Bhubaneswar, Odisha, India.ORCID https://orcid.org/0000-0003-4947-2335
Joy BanerjeeEzeRx Health Tech Pvt. Ltd, Bhubaneswar, Odisha, India.ORCID https://orcid.org/0000-0002-2629-2705
Sandeep SharmaEzeRx Health Tech Pvt. Ltd, Bhubaneswar, Odisha, India.ORCID https://orcid.org/0009-0009-2327-4964

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Anaemia is a major public health problem, especially in resource constrained settings. Dependency on assessment of blood hemoglobin (Hgb) concentration impedes anemia detection, risk stratification and intervention. Thus, valid, frugal and scalable technologies are needed. EzeCheck is a noninvasive portable device developed in India for predicting hemoglobin levels in human beings aged 4 years and above using a finger-tip biosensor. In this assessment, we aimed to: (i) evaluate EzeCheck's performance with an automated whole blood hemato-analyzer (Sysmex XN 1000) as the gold standard, and (ii) estimate EzeCheck's agreement with Sahli's method and HemoCue (Hb-301) in real-world primary and higher care facilities. Paired assessments were done at five sites across India i.e., Bhubaneshwar, Shimla, Solan and Mashobra and Ulhasnagar. Participants across all age groups (4 years and above) were assessed. We used a range of statistical tests to evaluate the performance of EzeCheck. It was found that EzeCheck performed well across age and gender categories with convincing validity, concordance, precision and accuracy, and acceptable bias. While comparing EzeCheck with Hemato-analyzer, no statistically significant systematic bias was found. However, EzeCheck showed significant systematic bias when compared to Sahli's method and HemoCue. We concluded that EzeCheck could detect anemia (as per WHO Hgb cut-offs) in 'real-world settings' and 'across age and gender categories', with high sensitivity, specificity and accuracy, and can serve as a replacement to traditional methods of hemoglobin assessment. Further, for countries with higher prevalence of anemia where universal screening may be mandated, the positive predictive value of EzeCheck will be higher. The likelihood ratios also indicated that the device had moderate-to-good utility. EzeCheck is suitable for embedment into program and out-patient health care settings in resource constrained contexts as a spot-check hemoglobinometer.

Identifiers

PMID38717987
PMCPMC11078411