Performance of the non-invasive point-of-care device, EzeCheck, for haemoglobin assessment in adults and children in community and institutional care settings.
Article in PLOS digital health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Towards noninvasive blood count using a deep learning pipeline from bulbar conjunctiva videos.NPJ digital medicine · 2026Article
- Evaluating the Feasibility and Cost-Effectiveness of EzeCheck for Hemoglobin Screening Across India.Cureus · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Anaemia is a major public health problem, especially in resource constrained settings. Dependency on assessment of blood hemoglobin (Hgb) concentration impedes anemia detection, risk stratification and intervention. Thus, valid, frugal and scalable technologies are needed. EzeCheck is a noninvasive portable device developed in India for predicting hemoglobin levels in human beings aged 4 years and above using a finger-tip biosensor. In this assessment, we aimed to: (i) evaluate EzeCheck's performance with an automated whole blood hemato-analyzer (Sysmex XN 1000) as the gold standard, and (ii) estimate EzeCheck's agreement with Sahli's method and HemoCue (Hb-301) in real-world primary and higher care facilities. Paired assessments were done at five sites across India i.e., Bhubaneshwar, Shimla, Solan and Mashobra and Ulhasnagar. Participants across all age groups (4 years and above) were assessed. We used a range of statistical tests to evaluate the performance of EzeCheck. It was found that EzeCheck performed well across age and gender categories with convincing validity, concordance, precision and accuracy, and acceptable bias. While comparing EzeCheck with Hemato-analyzer, no statistically significant systematic bias was found. However, EzeCheck showed significant systematic bias when compared to Sahli's method and HemoCue. We concluded that EzeCheck could detect anemia (as per WHO Hgb cut-offs) in 'real-world settings' and 'across age and gender categories', with high sensitivity, specificity and accuracy, and can serve as a replacement to traditional methods of hemoglobin assessment. Further, for countries with higher prevalence of anemia where universal screening may be mandated, the positive predictive value of EzeCheck will be higher. The likelihood ratios also indicated that the device had moderate-to-good utility. EzeCheck is suitable for embedment into program and out-patient health care settings in resource constrained contexts as a spot-check hemoglobinometer.