Evidence map›Paper›PMID 38715659›Full record

ArticlePractical laboratory medicine2024

Performance evaluation of the Access HBsAg and Access HBsAg confirmatory assays on the DxI 9000 Access Immunoassay Analyzer.

Benoit Visseaux, Jérémie Gautier, Françoise Le Boulaire, Catherine Coignard, Claire Vincent, Sandrine Gréaume, Isabelle Voisin, Veronique Lemée, Jean-Christophe Plantier, Yves-Edouard Herpe and 5 more

Abstract read
In one paragraph

Article in Practical laboratory medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Benoit VisseauxLaboratoire Cerba, Saint-Ouen l'Aumône, France.
Jérémie GautierCerba Xpert, Saint-Ouen l'Aumône, France.
Françoise Le BoulaireCerba Xpert, Saint-Ouen l'Aumône, France.
Catherine CoignardInfectology, Specialized CoreLab Department, Eurofins Biomnis, Ivry-Sur-Seine, France.
Claire VincentBiomnis Sample Library Department, Eurofins Biomnis, Ivry-Sur-Seine, France.
Sandrine GréaumePLER Laboratory, Etablissement Français du Sang Hauts-de-France, Normandie, Bois Guillaume, France.
Isabelle VoisinPLER Laboratory, Etablissement Français du Sang Hauts-de-France, Normandie, Bois Guillaume, France.
Veronique LeméeLaboratoire de Virologie, Institut de Biologie Clinique, Hôpital C. Nicole CHU Rouen, Rouen, France.
Jean-Christophe PlantierLaboratoire de Virologie, Institut de Biologie Clinique, Hôpital C. Nicole CHU Rouen, Rouen, France.
Yves-Edouard HerpeCentre de Ressources Biologiques Biobanque de Picardie, CHU Amiens Picardie, Amiens, France.
Etienne BrochotLaboratoire de Virologie, Centre de Biologie Humaine, CHU Amiens Picardie, Amiens, France.
Stephanie BordR&D Department, Beckman Coulter, Immunotech, Marseille, France.
Marc TuriniR&D Department, Beckman Coulter, Immunotech, Marseille, France.
Vanessa RouletClinical Affairs Department, Beckman Coulter, Immunotech, Marseille, France.
Juliane HeyClinical Affairs Department, Beckman Coulter, Immunotech, Marseille, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: This study evaluated the clinical and analytical performances of the Access HBsAg and the Access HBsAg Confirmatory assays on the DxI 9000 Access Immunoassay Analyzer (Beckman Coulter, Inc.). Materials and methods: Diagnostic specificity and sensitivity of the Access HBsAg and Access HBsAg Confirmatory assays were evaluated by comparing the Access assays to the final HBsAg sample status determined using the Architect, PRISM, or Elecsys HBsAg assays, along with Architect or PRISM HBsAg Confirmatory assays. Imprecision, sensitivity on seroconversion panels, analytical sensitivity on WHO, and recognition of HBV variants were also evaluated. Results: A total of 7534 samples were included in the analysis (6047 blood donors, 1032 hospitalized patients, 455 positive patients' samples). Access HBsAg assay sensitivity and specificity were at 100.00% (99.19-100.0) and 99.92% (99.82-99.97), respectively. Sensitivity of Access HBsAg Confirmatory assay was 100.00% (99.21-100.0) on the 464 HBsAg positive samples. The use of a high positive algorithm for the Access HBsAg assay, wherein samples with S/CO ≥ 100.00 were considered positive without requiring repeat or confirmatory testing, was successfully evaluated with all 450 specimens with S/CO greater than 100.00 (sensitivity 100.00%; 99.19-100.0). Access HBsAg assay demonstrated good analytical performance, equivalent recognition of seroconversion panels compared to Architect assay, and an analytical sensitivity between 0.022 and 0.025 IU/mL. All HBV genotypes, subtypes and mutants were well detected without analytical sensitivity loss. Conclusion: Access HBsAg and Access HBsAg Confirmatory assays demonstrated robust performances. They provide low samples volume requirements and a simplified process, no systematic retesting for high positive samples.

Indexed as

Analytical performancesChemiluminescence immunoassayClinical performancesHBsAgHepatitis B infection

Identifiers

PMID38715659
PMCPMC11075052

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked