Evidence map›Paper›PMID 38715658›Full record

ArticlePractical laboratory medicine2024

Comparison of Labsan Tricell-1000 and Dirui FUS-2000 automated urine analyzers with manual microscopy.

Sedat Abusoglu, Halil Guven, Busra Ecer, Ahmet Emre Yorulmaz, Abdullah Sivrikaya, Fatma Humeyra Yerlikaya Aydemir, Ali Unlu, Gulsum Abusoglu, Muhittin Abdulkadir Serdar

Abstract read
In one paragraph

Article in Practical laboratory medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sedat AbusogluDepartment of Biochemistry, Selcuk University Faculty of Medicine, Konya, Turkey.
Halil GuvenDepartment of Biochemistry, Selcuk University Faculty of Medicine, Konya, Turkey.
Busra EcerDepartment of Biochemistry, Selcuk University Faculty of Medicine, Konya, Turkey.
Ahmet Emre YorulmazDepartment of Biochemistry, Selcuk University Faculty of Medicine, Konya, Turkey.
Abdullah SivrikayaDepartment of Biochemistry, Selcuk University Faculty of Medicine, Konya, Turkey.
Fatma Humeyra Yerlikaya AydemirDepartment of Biochemistry, Selcuk University Faculty of Medicine, Konya, Turkey.
Ali UnluDepartment of Biochemistry, Selcuk University Faculty of Medicine, Konya, Turkey.
Gulsum AbusogluDepartment of Medical Laboratory Techniques, Selcuk University, Turkey.
Muhittin Abdulkadir SerdarDepartment of Biochemistry, Acıbadem University, İstanbul, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Urinalysis is a first-line test for screening for urinary tract infection. Several devices performing strip and sediment analysis have been introduced. The aim of this study was to compare the performance of Labsan Tricell-1000 and Dirui FUS-2000 automated urine analyzers with manual microscopy. Methods: 463 urine samples were analyzed. Digital image processing and particle recognition automatically display the cells in a flowing sheath fluid mixed monolayer urine sample, take the pictures of particles via digital camera, analyse these pics with a particle recognition software, transfer images of the formed elements to the screen and allow well-trained personnel to select, reclassify or remove them. Manual microscopy was used for comparison. Results: Agreement between Tricell-100 and manual microscopy was very good for RBC (ϰ = 0.80), and WBC (ϰ = 0.83); good for CaOx (ϰ = 0.69), SEC (ϰ = 0.80), YLC (ϰ = 0.72), HC (0.69) and LC (ϰ = 0.64); moderate for BAC (ϰ = 0.51), APC (ϰ = 0.43) and MT (ϰ = 0.55); fair for GC (ϰ = 0.39) and RTEC (ϰ = 0.32). Conclusions: Labsan Trion TriCell-1000 demonstrated satisfactory performance and can be used in routine urinalysis. In the case of low counts of RBC, presence of yeast, crystal, casts or cell clumping in urine sediment, characterization of urine particles should be performed by manual microscopy.

Indexed as

ConcordanceKappaParticle recognitionUrinalysis

Identifiers

PMID38715658
PMCPMC11075057

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked