Evidence map›Paper›PMID 38714707›Full record

ArticleScientific reports2024

Lens-free reflective topography for high-resolution wafer inspection.

Hojun Lee, Jangwoon Sung, Seungbeom Park, Junho Shin, Hyungjin Kim, Wookrae Kim, Myungjun Lee

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Ultrafast Dynamic Defect Inspection With Computational Neuromorphic Imaging.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hojun Lee *Mechatronics Research, Samsung Electronics Co., Ltd., 1-1 Samsungjeonja-ro, Hwaseong-si, Gyeonggi-do, 18848, Korea. hojun86.lee@samsung.com.
Jangwoon Sung *Mechatronics Research, Samsung Electronics Co., Ltd., 1-1 Samsungjeonja-ro, Hwaseong-si, Gyeonggi-do, 18848, Korea.
Seungbeom ParkMechatronics Research, Samsung Electronics Co., Ltd., 1-1 Samsungjeonja-ro, Hwaseong-si, Gyeonggi-do, 18848, Korea.
Junho ShinMechatronics Research, Samsung Electronics Co., Ltd., 1-1 Samsungjeonja-ro, Hwaseong-si, Gyeonggi-do, 18848, Korea.
Hyungjin KimMechatronics Research, Samsung Electronics Co., Ltd., 1-1 Samsungjeonja-ro, Hwaseong-si, Gyeonggi-do, 18848, Korea.
Wookrae KimMechatronics Research, Samsung Electronics Co., Ltd., 1-1 Samsungjeonja-ro, Hwaseong-si, Gyeonggi-do, 18848, Korea.
Myungjun LeeMechatronics Research, Samsung Electronics Co., Ltd., 1-1 Samsungjeonja-ro, Hwaseong-si, Gyeonggi-do, 18848, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The demand for high-resolution and large-area imaging systems for non-destructive wafer inspection has grown owing to the increasing complexity and extremely fine nature of semiconductor processes. Several studies have focused on developing high-resolution imaging systems; however, they were limited by the tradeoff between image resolution and field of view. Hence, computational imaging has arisen as an alternative method to conventional optical imaging, aimed at enhancing the aforementioned parameters. This study proposes a method for improving the resolution and field of view of an image in a lens-less reflection-type system. Our method was verified by computationally restoring the final image from diffraction images measured at various illumination positions using a visible light source. We introduced speckle illumination to expand the numerical aperture of the entire system, simultaneously improving image resolution and field of view. The image reconstruction process was accelerated by employing a convolutional neural network. Using the reconstructed phase images, we implemented high-resolution topography and demonstrated its applicability in wafer surface inspection. Furthermore, we demonstrated an ideal diffraction-limited spatial resolution of 1.7 μm over a field of view of 1.8 × 1.8 mm

Identifiers

PMID38714707
PMCPMC11076508

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.