Evidence map›Paper›PMID 38714704›Full record

ArticleScientific reports2024

Early thrombus detection in the extracorporeal membrane oxygenation circuit by noninvasive real-time ultrasonic sensors.

Gongmin Rim, Kwanyong Hyun, Deog Gon Cho, Zhongsoo Lim, Byungdoo Lee, Keunho Kim, Ga Young Yoo

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Gongmin RimDepartment of Thoracic and Cardiovascular Surgery, The Catholic University of Korea, St. Vincent's Hospital, 93 Jungbu-Daero, Paldal-gu, Suwon-si, Gyeonggi-do, 16247, Republic of Korea.
Kwanyong Hyun *Department of Thoracic and Cardiovascular Surgery, The Catholic University of Korea, St. Vincent's Hospital, 93 Jungbu-Daero, Paldal-gu, Suwon-si, Gyeonggi-do, 16247, Republic of Korea. k.hyun@catholic.ac.kr.
Deog Gon Cho *Department of Thoracic and Cardiovascular Surgery, The Catholic University of Korea, St. Vincent's Hospital, 93 Jungbu-Daero, Paldal-gu, Suwon-si, Gyeonggi-do, 16247, Republic of Korea. cscho@catholic.ac.kr.
Zhongsoo LimTFYHNN, Pohang, Republic of Korea.
Byungdoo LeeDepartment of Thoracic and Cardiovascular Surgery, The Catholic University of Korea Seoul St. Mary's Hospital, Seoul, Republic of Korea.
Keunho KimDepartment of Thoracic and Cardiovascular Surgery, The Catholic University of Korea Seoul St. Mary's Hospital, Seoul, Republic of Korea.
Ga Young YooDepartment of Thoracic and Cardiovascular Surgery, The Catholic University of Korea Seoul St. Mary's Hospital, Seoul, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Thrombus formation in extracorporeal membrane oxygenation (ECMO) remains a major concern as it can lead to fatal outcomes. To the best of our knowledge, there is no standard non-invasive method for quantitatively measuring thrombi. This study's purpose was to verify thrombus detection in an ECMO circuit using novel, non-invasive ultrasonic sensors in real-time, utilizing the fact that the ultrasonic velocity in a thrombus is known to be higher than that in the blood. Ultrasonic sensors with a customized chamber, an ultrasonic pulse-receiver, and a digital storage oscilloscope (DSO) were used to set up the measuring unit. The customized chamber was connected to an ECMO circuit primed with porcine blood. Thrombi formed from static porcine blood were placed in the circuit and ultrasonic signals were extracted from the oscilloscope at various ECMO flow rates of 1-4 L/min. The ultrasonic signal changes were successfully detected at each flow rate on the DSO. The ultrasonic pulse signal shifted leftward when a thrombus passed between the two ultrasonic sensors and was easily detected on the DSO screen. This novel real-time non-invasive thrombus detection method may enable the early detection of floating thrombi in the ECMO system and early management of ECMO thrombi.

Indexed as

Extracorporeal Membrane OxygenationThrombosisAnimalsSwineUltrasonicsUltrasonographyExtracorporeal membrane oxygenationReal-time non-invasive thrombus detectionThrombusTravel time differenceUltrasonic sensors

Identifiers

PMID38714704
PMCPMC11076605

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.