Descriptive analysis of incidence and risk factors for short intramedullary nail breakage in femoral intertrochanteric fractures: a multicenter (TRON group) retrospective study.

Hirokazu Noritake, Yasuhiko Takegami, Katsuhiro Tokutake, Hiroaki Nakashima, Kenichi Mishima, Takanori Ito, Shiro Imagama

Abstract readMulticenter Study
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hirokazu NoritakeDepartment of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
Yasuhiko TakegamiDepartment of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan. takegami@med.nagoya-u.ac.jp.ORCID http://orcid.org/0000-0001-9279-8301
Katsuhiro TokutakeDepartment of Hand Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Hiroaki NakashimaDepartment of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
Kenichi MishimaDepartment of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
Takanori ItoDepartment of Orthopaedic Surgery, Tsushima City Hospital, Tsushima, Japan.
Shiro ImagamaDepartment of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe incidence of hip fractures is increasing. Femoral intertrochanteric fractures make up 50% of hip fractures and are treated by intramedullary nails. Implant breakage is a recognized complication that can have rare and serious implications. This study aimed to investigate implant breakage rates after surgical treatment for femoral intertrochanteric fractures.

methodsThis was a retrospective multicenter analysis. All 1854 patients who underwent surgical treatment for femoral intertrochanteric fractures were selected from 12 hospitals (TRON group) between 2016 and 2020. Exclusion criteria included implants other than those specified and follow-up periods less than three months. Demographic data, surgical details, and radiographic assessments were collected from medical records and X-ray evaluations.

resultsAmong the 983 study patients, consisting of 245 males (24.9%) and 738 females (75.1%), the implant breakage rate was 0.31%, with three confirmed cases. The average age was 83.9 years. The mean follow-up period was 640.9 days. Two cases were linked to ASULOCK implants, and one to an OLSII implant. Statistical analysis showed a significantly higher incidence of ASULOCK implant breakage (p < 0.001). In the two cases of ASULOCK implant breakage and one case of OLSII implant breakage, breakage in all three implants occurred at the anti-rotation screws.

conclusionsThere were no implant breakages of the main body of the implants; all breakages occurred in the additional anti-rotation screw. The necessity of the anti-rotation screw will require further discussion. These results can potentially inform clinical decisions and guide further research in preventing implant breakage.