Performance Comparison of Augmented Reality Versus Ultrasound Guidance for Puncture: A Phantom Study.

Laetitia Saccenti, Hugo Bessy, Bilel Ben Jedidia, Benjamin Longere, Lionel Tortolano, Haytham Derbel, Alain Luciani, Hicham Kobeiter, Thierry Grandpierre, Vania Tacher

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Cardiovascular and interventional radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Laetitia SaccentiImagerie Medicale, Hopital Henri Mondor, Creteil, France. laetitia.saccenti@aphp.fr.ORCID http://orcid.org/0000-0002-9765-0039
Hugo BessyImagerie Medicale, Hopital Henri Mondor, Creteil, France.
Bilel Ben JedidiaImagerie Medicale, Hopital Henri Mondor, Creteil, France.
Benjamin LongereDepartment of Cardiovascular Radiology, CHU Lille, 59000, Lille, France.
Lionel TortolanoImagerie Medicale, Hopital Henri Mondor, Creteil, France.
Haytham DerbelImagerie Medicale, Hopital Henri Mondor, Creteil, France.
Alain LucianiImagerie Medicale, Hopital Henri Mondor, Creteil, France.
Hicham KobeiterImagerie Medicale, Hopital Henri Mondor, Creteil, France.
Thierry GrandpierreEcole superieure d'ingenieurs en electrotechnique et electronique, ESIEE Paris, Noisy Le Grand, France.
Vania TacherImagerie Medicale, Hopital Henri Mondor, Creteil, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAugmented reality (AR) is an innovative approach that could assist percutaneous procedures; by directly seeing "through" a phantom, targeting a lesion might be more intuitive than using ultrasound (US). The objective of this study was to compare the performance of experienced interventional radiologists and operators untrained in soft tissue lesion puncture using AR guidance and standard US guidance. MATERIAL AND

methodsThree trained interventional radiologists with 5-10 years of experience and three untrained operators performed punctures of five targets in an abdominal phantom, with US guidance and AR guidance. Correct targeting, accuracy (defined as the Euclidean distance between the tip and the center of the target), planning time, and puncture time were documented.

resultsAccuracy was higher for the trained group than the untrained group using US guidance (1 mm versus 4 mm, p = 0.001), but not when using AR guidance (4 mm vs. 4 mm, p = 0.76). All operators combined, no significant difference was found concerning accuracy between US and AR guidance (2 mm vs. 4 mm, p = 0.09), but planning time and puncture time were significantly shorter using AR (respectively, 15.1 s vs. 74 s, p < 0.001; 16.1 s vs. 59 s; p < 0.001).

conclusionUntrained and trained operators obtained comparable accuracy in percutaneous punctures when using AR guidance whereas US performance was better in the experienced group. All operators together, accuracy was similar between US and AR guidance, but shorter planning time, puncture time were found for AR guidance.

Indexed as

Augmented RealityPhantoms, ImagingPuncturesUltrasonography, InterventionalClinical CompetenceHumansAugmented realityImage-guided therapyInterventional radiologyPercutaneous procedure