Evidence map›Paper›PMID 38710768›Full record

ArticleJournal of exposure science & environmental epidemiology2025

The application of PTR-MS and non-targeted analysis to characterize VOCs emitted from a plastic recycling facility fire.

Eva C M Vitucci, Oladayo Oladeji, Albert A Presto, Carolyn L Cannon, Natalie M Johnson

Abstract read
In one paragraph

Article in Journal of exposure science & environmental epidemiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Eva C M VitucciDepartment of Environmental and Occupational Health, Interdisciplinary Faculty of Toxicology, Texas A&M University, College Station, TX, 77843, USA.
Oladayo OladejiDepartment of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA.
Albert A PrestoDepartment of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA.
Carolyn L CannonDepartment of Microbial Pathogenesis and Immunology, School of Medicine, Texas A&M University, Bryan, TX, 77807, USA.
Natalie M JohnsonDepartment of Environmental and Occupational Health, Interdisciplinary Faculty of Toxicology, Texas A&M University, College Station, TX, 77843, USA. nmjohnson@tamu.edu.ORCID http://orcid.org/0000-0001-8584-9713

Funding

Single cell, multi-parametric high throughput platform to classify endocrine disruptor potential of mixturesP42ES027704 · NIEHS · TEXAS A&M UNIVERSITY · PI Efstratios Pistikopoulos · 2017 to 2026
$21.2M
Texas A&M Center for Environmental Health Research (TiCER)P30ES029067 · NIEHS · TEXAS A&M UNIVERSITY · PI Sakhila Banu · 2019 to 2026
$13.0M
Regulatory Science in Environmental Health and ToxicologyT32ES026568 · NIEHS · TEXAS A&M UNIVERSITY · PI Weihsueh A Chiu, Natalie M Johnson · 2016 to 2026
$3.8M
NIEHS NIH HHS P30 ES029067NIEHS NIH HHS P42 ES027704NIEHS NIH HHS T32 ES026568
6 · The paper itself

Abstract

backgroundOn April 11th, 2023, the My Way Trading (MWT) recycling facility in Richmond, Indiana caught fire, mandating the evacuation of local residents and necessitating the U.S. Environmental Protection Agency (EPA) to conduct air monitoring. The EPA detected elevated levels of plastic combustion-related air pollutants, including hydrogen cyanide and benzene.

objectiveWe aimed to identify these and other volatile organic compounds (VOCs) present as well as to identify the potential hazard of each compound for various human health effects.

methodsTo identify the VOCs, we conducted air monitoring at sites within and bordering the evacuation zone using proton transfer reaction mass spectrometry (PTR-MS) and non-targeted analysis (NTA). To facilitate risk assessment of the emitted VOCs, we used the EPA Hazard Comparison Dashboard.

resultsWe identified 46 VOCs, within and outside the evacuation zone, with average detection levels above local background levels measured in Middletown, OH. Levels of hydrogen cyanide and 4 other VOCs were at least 1.8-fold higher near the incidence site in comparison to background levels and displayed unique temporal and spatial patterns. The 46 VOCs identified had the highest hazardous potential for eye and skin irritation, with approximately 45% and 39%, respectively, of the VOCs classified as high and very high hazards for these endpoints. Notably, all detected VOC levels were below the hazard thresholds set for single VOC exposures; however, hazard thresholds for exposure to VOC mixtures are currently unclear. IMPACT: This study serves as a proof-of-concept that PTR-MS coupled with NTA can facilitate rapid identification and hazard assessment of VOCs emitted following anthropogenic disasters. Furthermore, it demonstrates that this approach may augment future disaster responses to quantify additional VOCs present in complex combustion mixtures.

Indexed as

Air PollutantsEnvironmental MonitoringFiresRecyclingVolatile Organic CompoundsHumansIndianaMass SpectrometryPlasticsRisk AssessmentUnited StatesUnited States Environmental Protection AgencyAir PollutantsPlasticsVolatile Organic CompoundsAir pollutionAnalytical methodsDisasterInhalation exposureVolatile organic compounds

Identifiers

PMID38710768
PMCPMC12009732

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.